11
Astra P-10 USER MANUAL
The minimum height of chimney from the stove’s smoke pipe to the chimney top is 4 meters. The recommended lengths of various
parts of combined internal/external flue are presented in Fig. 9.
6. TRANSPORTATION, STORAGE, UNPACKING
The stove is to be transported and packaged in original packaging of the manufacturer, protected from precipitation and dust. It
must be transported only in the vertical position, fastened to avoid sliding and falling. If the stove is transported any other way,
decorative surfaces may be damaged, cladding battered, control and regulation equipment broken, or the fire pot may fall down and
harm the vermiculite plates. The appliance should be carefully loaded, unloaded and transported, to avoid any significant impact.
The stoves can be loaded one on the top of another, because the packaging is designed so that the stoves may be transported and
stored in two decks. However, loading other objects on the top is prohibited as the packaging frame of the stove has been designed
specifically to support the same stove.
The stove should also be stored in a vertical position, in a closed room protected from precipitation. The air humidity of the room
should not exceed 80%, in order to avoid condensate forming on the surfaces of the appliance. Storage temperatures may vary from
-40 °C to +60 °C. If the stove was transported or stored in sub-zero temperatures, then it should be moved to a place above zero for
no less than 2 hours before being used.
After the stove is delivered to the site, take off the packing frame and polyethylene film, remove the stove from the packaging base.
Then check if all elements listed in a delivery kit are included. The delivery kit consists of the following: stove - 1 pc.; cable with plug
for electrical connection - 1 pc.; fire pot - 1 pc.; protective handle - 1 pc.; user manual - 1 pc.; remote control (only when ordered
separately) - 1 pc.
The user manual is an integral part of the stove. Please, make sure that it remains with the stove, including
cases when it is transferred to another user or another place.
Check to ensure that painted surfaces have not been damaged during transportation, that the components are not bent, and that
the control and regulation equipment is intact. If you notice any damage or discrepancies, present your claims to the vendor company.
7. KINDLING
Connect the stove to the electrical supply and turn on the switch 3 on the lower half of the rear panel of the stove (Fig. 19). Lift the
lid of the pellet hopper, put the opened end of a pellet sack on the hopper aperture and fill it. Avoid spilling pellets into ventilation
Fig. 9
Recommended lengths of parts of a combined internal/external flue
YES
NO
FIG.6
FIG.9
YES
FIG.10
FIG.5
NO
FIG.8
YES
YES
FIG.7
2500 mm
.
max.
H > 4000 mm H > 1500 mm
8
3
4
1
2
9
10
11
5
7
6
12
Insulated flue
Insulated chimney tee with
condensation drain pipe
Chimney tee with a cap and a
peephole