23
Astra P-10 USER MANUAL
who has installed the stove.
Use a drum-type vacuum cleaner only.
The flue of the stove has two channels: at the left and at the right side
of the combustion chamber. These channels join together into one smoke
passage box near which the exhaust fan 16 (Fig. 1) is mounted. To access
the inspection hatches of the flue channels, both lateral panels and top
cover of the stove must be removed. Before removing the top cover of
the stove, the display has to be taken out and disconnected. Work in the
following order:
1. Lift the lid of the pellet hopper and disconnect the cable of the
display (Fig. 17a).
2. Unscrew two M5 screws, pull towards yourself and remove the
rooftop cover (Fig. 17).
The display is connected to the controller board by RJ11
type data cable connection sitting on the bottom part
of the display (Fig. 17a). Do not forget to disconnect the cable
before removing the rooftop cover of a stove.
3. Remove the lateral panels of the stove. Unscrew six M5 bolts fastening
the panels on the rear side of the stove (Fig. 18a). Unscrew two M5 bolts
on the top (Fig. 18b). Then, lift and remove the lateral panels.
4. Open all four inspection hatches. Unscrew pairs of M5 bolts; remove
gaskets and inspection lids (Fig. 18c). Clean the flue channels in both
sides of the stove.
• PELLET HOPPER PROTECTION AGAINST BURNING
The pellet hopper has a protection from overheating and burning: the temperature sensor 6 and the thermostat 12 (Fig.1). They
operate independently from the controller. If for any reason the hopper starts overheating the thermostat stops the stove by
interrupting the electrical supply.
To restart operation of the stove, remove the thermostat cover 2 (Fig. 19) and depress the button behind it.
• PROTECTIVE HANDLE
Use this handle as a tool, when pulling the scraper’s handle out of the front grate and removing the hot ashes drawer. To pull out the
drawer, hook the handle on a ledge near the special notch (Fig. 20).
1
2
3
Fig. 19
1. Protective handle; 2. Safety thermostat; 3. Electrical
supply switch.
Fig. 20
Cleaning the heat exchanger tubes.