17
Astra P-10 USER MANUAL
The anti-freeze mode is operational only with the weekly timer mode. The timer programs can be
undescribed but the timer mode must be switched on.
The current temperature of smoke is shown on the screen.
The current value of the smoke temperature.
• OUTPUT POWER REGULATION
To view the burning power setting, press
button to enter the Power menu section. There are six power
levels. The stove increases burning power by raising the quantity of pellets being transported by the auger per
time period and the quantity of supplied air for combustion simultaneously. If the target room temperature is set,
the stove chooses the optimal burning power level itself. The stove lowers the burning power level itself for better
economy, after the target room temperature has been achieved. By default, when you do not set the power level
manually the stove controller returns to the automatic power mode. To change power level press button and
use
buttons to increase/decrease the selected values.
The first output level.
The second output level.
The third output level.
The fourth output level.
If the desired room temperature is set, the stove chooses the optimal output level itself. “Auto” indication shines
on the screen..
If a cold room needs to be warmed up fast, set the maximum output level “High”.
The burning power level can be set and changed with remote control as well.
Scroll the output power menu by pressing the
buttons.
The indication pane exhibits the current operational status of the stove:
The stove is switched off.
The stove is in the ignition phase (rising column).
The stove is in the shutdown phase (descending column).
The stove is in the operation phase. A current output power in
kW is shown on the pane.
Scroll the output power menu by pressing the
buttons.
Economy mode. The stove operates with modulation in this mode but shuts down when the set room temperature
is reached. If required, the stove turns on again.
When the economy mode is switched off, the stove operates with modulation but never shuts down completely,
even when the set room temperature is exceeded by more than 1°C.:
The economy mode is switched on.
The economy mode is switched off.