SPECIFICATIONS
16
11. Software calibration control.
The 4500D is calibrated through the front panel keypad. All calibration information is
stored in non-volatile memory. This allows the 4500D to be completely calibrated
without removing any covers and exposing the technician to hazardous voltages.
12. User selectable output voltage frequencies of 50 or 60 hertz.
The 4500D is designed for the global market. This feature makes it simple for the user
to select the output frequency in the AC hipot mode so that products can be tested at
the same frequency they will be used at.
13. Output voltage fine adjustment.
To make 4500D usable in all types of applications, the operator can manually bring the
voltage up or down in 10 volt increments by simply pressing the up and down arrow
keys. This makes it very easy to adjust the output voltage even while the 4500D is in
the dwell mode so you can analyze test results at different voltages.
14. Built-in Continuity test mode.
The 4500D meets ground continuity test requirements called out by UL and other
safety agencies.
15. Flashing high voltage indicator.
A flashing LED located directly over the high voltage terminal clearly indicates when
high voltage is active to provide maximum operator safety.
16. Comes complete with a test box for products terminated in a line cord.
The standard US style receptacle box allows easy testing of hipot and continuity on
line cord terminated products. As an additional benefit, termination boxes are
available for testing products with line cords configured for other countries.
17. User selectable input voltage.
The 4500D can be switched for either 115 or 230 volt input operation through an easy
access rear panel mounted switch to allow it to be used in any country.
18. Low-current sense.
Monitors the minimum level of current flow, thus ensuring that the DUT is properly
connected and that the hipot test is being performed.
19. Electronic ramping.
Provides a gradual and timed method to increase output voltage to the DUT,
minimizing any damage from quickly over-applying high voltage to sensitive DUTs.
20. Test setup memories.
The operator can store and recall test setups, thus eliminating the need to re-enter
setup information.
21. Built-In Remote Interlock
A remote interlock provides a way to connect a safety enclosure or other safety device
to protect the operator from exposure to high voltage.