7-8
SORGENTE/SMILE/ISI-T/UNDERCOUNTER - Installation, Use and Maintenance - cod. A-MAN03 - Rev. 02/2012
7.3.5
Resyncing of the remote control
First, verify that the alkaline battery is installed in the
remote control (type 23A 12V)
1. Disconnect the power supply.
2. Press - and hold - the back programming key.
3. Reconnect the power supply.
4. Press for a few seconds one of three buttons on the
remote control.
5. The remote control is now resynched.
PROBlEM
sOlUTION
by pressing any key of the remote
control the operation led illuminates
but the dispenser does not dispense
and does not emit any acoustic signal.
try to move the remote control closer to
the equipment and press againa key; if
the dispensing starts replace the battery
of the remote controlor try to position
the remote control closer to the device.
If the device still does not dispense
make sure that the device is powered
by pressing the programming key and
waiting for the set up beep (see par.
7.3.3 and 7.3.5), if a beep is heard the
equipment
is powered, instead check the plugs and
the power connection cable.
by pressing any key of the remote
control the dispenser does not
dispense and the operation led of the
remote control is not illuminated.
remote control battery low
or damaged remote control.
the remote control interferes with
other systems operated by remote
control or vice versa.
change the codes of the other devices or
ask the dispenser manufacturer to supply
a remote control with different codes.
by pressing any key of the remote
control the device emits acoustic
signals.
compare the signals with the failure
signals or acoustic alarms table (see par.
7.3.4) to determine the problem.