6-2
SORGENTE/SMILE/ISI-T/UNDERCOUNTER - Installation, User and Maintenance - cod. A-MAN03 - Rev. 02/2012- Rev. 02/2012
For a correct use of the touch-screen key pad touch the key
in a decisive way
with the finger
(see picture at side)
.
If the finger touches the key slowly or laterally, the key will not
consider it valid and therefore the dispensing will not occur.
The touch keys for dispensing, keypad lock, anomaly led
and display are positioned on the upper front part of the
dispenser.
(fig. 6.1)
.
During standard operation the display is on and illuminated
with blue light and the dispensing keys are illuminated with
a white light
On the back side of the dispenser
(fig. 6.2)
there are the
keys for setting the temperature of the cold still and cold
sparkling water (1) and the fissure for inserting the smart
card (2).
6.1.1. Anomalies signalling led
Above the room temperature and cold water dispensing
keys, there are two leds that indicate possible failures
which illuminate with fixed or intermittent light in ac-
cordance with the problem to signal
(fig. 6.3)
.
led 1
at left above the dispensing key
is for the filter
pre-alarm and blockage for exhausted filter.
led 2
at right above the
key indicates the alarms with
codes and short description (see DIAGNOSTICS chapter).
fig. 6.3
Led 2
Led 1
fig. 6.2