IN120 Exit Device
Operational Check
8
1. Insert key into cylinder and rotate (Fig. 15A).
There should be no friction against lock case, wire
harness or any other obstructions.
2. Check that the key retracts the latch.
3. The key should rotate freely.
4. Try the inside lever; ensure it retracts latch.
5. Use a valid credential* set up with the
Lock Configuration
Tool
to unlock outside lever and retract latch.
Refer to
Network and Lock Configuration
Tool
user manual (
WFMN1
) for information on
how to configure and program locks.
*
Twenty (20) seconds after lock initialization
(single beep with lock motor actuation).
Note: The credential should approach the inscription
on the reader as indicated (Fig. 15B) to ensure
the credential is read properly.
Do not wave credential.