IN120 Exit Device
Fig. 5
3 Mount Mortise & Exit Device Chassis
Inside of Door
(2) 1/4 x 2-3/8”
Flathead Machine
Screws (secures ET)
Exit Chassis
Fig. 3A
1. Slide mortise lock into door and loosely secure with (2) flat head screws.
NOTE: Exit chassis harness consists of a 6-pin female connector and
ground lug (Fig. 3A)
2. Feed 6-pin connector and
larger
ground lug straight through to outside
of door (Fig. 3A, B) while feeding smaller ground lug into wire hole, up
through wire channel and out through inside of door (Fig. 3A).
DO NOT PINCH THE WIRE HARNESS.
3. Begin to secure the exit chassis with through bolts
to the ET trim using (2) 1/4 -20 x 2-3/8”
flat head machine screws.
Fig. 3B Detail
Latch Bolt
Chassis
Chassis Lift Lever
Lever