04/30/16
15 1-800-810-WIRE • www.sargentlock.com • A8185A
Copyright © 2016, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
IN120 Exit Device
1. Tuck excess cable into wire hole on inside of door.
2. Secure the mounting assembly while ensuring proper
alignment of outside reader and fully tighten the (2) through-
bolts on the inside of the door to secure the reader and plate
to the door.
Secure the following connectors to their respective terminals (Fig. 9A, B):
A. Secure the 4-pin DPS connector.
B. Secure the 10-pin lock body assembly connector.
CAUTION - Do not touch or allow debris to enter connector contacts.
Secure Mounting Plate
IMPORTANT: Do not run wires through bottom hole in plate (Fig. 9A, B)
- it will damage wires and the controller connector. Route wires around
flange, do not route wires through the flange hole (Fig. 9B).
C. Secure the 24-pin card reader connector (Fig. 9B).
10 Installation of Connectors
Ground
Lug
DPS (4-pin)
A
Lock
Body
(10-pin)
Fig. 9A
B
Reader
(24-pin)
Board-to-Board
Connector
Fig. 9B
C
*NOTE: Optional 2-pin external 9-24VDC power connector.
9-24VDC
Power*