53
Function and operation
EN
Examples of use
The following examples demonstrate possibilities for using the
motorised multi-point lock 519N
with the
OneSystem IO module N5950
and the
fire protection module 519ZBFS
.
Barrier-free doors
When combined with the
OneSystem IO module N5950
and a swing door drive, the
motorised multi-point
lock 519N
offers the possibility of installing a barrier-free door, e.g. for use in a hospital.
Connection version 1 for barrier-free doors
The motorised unlocking of the lock takes place with a release button. The
swing door drive
control output
is then actuated and the door opens.
The door is closed again with the time-controlled swing door drive, and the mechanical automatic locking
function secures the door.
Connection version 2 for barrier-free doors
The revolving door drive receives the
open door
command via a release button or radar sensor and sends
an unlock command to the
motorized multi-point lock 519N
.
The lock is unlocked and then sends feedback
to the revolving door drive via the
unlocked
control output. The revolving door drive opens the door.
The time-controlled revolving door drive closes the door again, the lock is locked automatically.
With connection version 2, day/night operation is also possible, for example, depending on the function of
the revolving door drive. The lock remains unlocked during the day and is locked at night.
Safely locking fire and smoke protection doors
Warning!
Life-threatening danger and risk of injury when there is no fire detector:
With use of the
motorised
multi-point lock 519N
in a fire or smoke protection door, the
OneSystem IO module N5950
, the
fire protection
module 519ZBFS
and a fire detector approved by inspection authorities must be used.
Life-threatening danger and risk of injury when there is no smoke detector:
With use of the
motorised
multi-point lock 519N
in a smoke protection door, the fire detector must react to smoke.
When combined with the
OneSystem IO module N5950
and the
fire door module
, the
motorised multi-point
lock 519
provides secure locking of a fire and smoke protection door. With actuation by means of a fire
alarm system or a fire detector, the alarm is issued and the lock is actuated by means of the
OneSystem IO
module N5950
.
The
fire protection module 519ZBFS
supplies the energy needed for locking in the event of a power failure.
If the
motorised multipoint lock 519N
has been locked by the
OneSystem IO module N5950
due to a fire
alarm, unlocking by means of the electric motor is only possible once the fire alarm has been reset.
In the case of a fire door with swing door drive, a fire alarm or a hold-open system with a fire detector
approved by inspection authorities is normally required. This actuates the swing door drive and the
motorised multi-point lock 519N
.
!
Содержание OneSystem 519N
Страница 31: ...31 Technische Daten DE ...
Страница 49: ...49 Notes EN Fig 2 OneSystem motorised multi point lock 519N Fig 3 Rebate gap B A 2 3 4 5 6 7 8 9 1 ...
Страница 67: ...67 Technical data EN ...
Страница 103: ...103 Caractéristiques techniques FR ...
Страница 121: ...121 Indicazioni IT Fig 2 Serratura motorizzata multipunto 519N Fig 3 Luce di funzionamento B A 2 3 4 5 6 7 8 9 1 ...
Страница 139: ...139 Dati tecnici IT ...
Страница 157: ...157 Aanwijzingen NL Afb 2 OneSystem meervoudig vergrendelingsmotorslot 519N Afb 3 Sponningspeling B A 2 3 4 5 6 7 8 9 1 ...
Страница 175: ...175 Technische gegevens NL ...
Страница 187: ...187 Abmessungen Dimensions Dimensions Dimensioni Afmetins DE EN FR IT NL ...