background image

KING COBRA-2

12-BUTTON WITH BEEPER

PROGRAMMING GUIDE

FORM 67050                                                                                                                               2/07

Содержание KING COBRA-2 KC5196-2-R

Страница 1: ...KING COBRA 2 12 BUTTON WITH BEEPER PROGRAMMING GUIDE FORM 67050 2 07 ...

Страница 2: ... desired see page 7 for additional information FUNCTION FACTORY DEFAULT DESCRIPTION PROGRAMMING NORMAL 9 7 5 3 1 1 3 5 7 9 NONE NONE NONE ONE USE SUPERVISED PASS THRU The programming code or iButton puts the lock into a programming mode It will not unlock the lock When a Programming code plus is entered the LEDs alternately flash several times indicating the lock is in a programming mode If more t...

Страница 3: ... default relock time delay will also be restored If the memory ever needs to be erased follow the steps below 1 Remove the inside escutcheon 2 Remove one battery 3 Press and hold the key 4 Reinstall the battery Red LED flashes 2 times Green LED illuminates and beeper sounds 4 Release the key 5 Reinstall the inside escutcheon ERROR CODE DESCRIPTION Note the beeper does not sound during error code i...

Страница 4: ...119 TO ADD NORMAL USE CODE ENTER NEW CODE TO ADD MORE TO END 3 Use the steps on this page to program codes into the lock This must be a unique 3 6 digit code The key is used like the ENTER key on a computer After press ing the key wait for the red and green LEDs to stop flashing before proceeding to the next step An error has occurred if the red LED stays on while the green LED flashes The flashin...

Страница 5: ...N ENTER iBUTTON 3 Use the steps on this page to program iButtons into the lock Note that each iButton must have a PIN associat ed with it This must be a unique 3 6 digit code It will not open the door and it can not be used as an access code It is important to record the PINs so that the iButton can be deleted if it is lost If at any time the red LED stays on while the green LED flashes an error h...

Страница 6: ...33 TO ADD LINKED NORMAL USE iBUTTON ENTER NEW PIN TO ADD MORE TO END 311 ENTER iBUTTON ENTER iBUTTON Use the steps on this page to program iButtons with Linked Access Linked Access adds a higher level of security in case an iButton gets lost or stolen To use a Linked Access iButton enter the iButton into the lock and then enter the PIN associated with it If at any time the red LED stays on while t...

Страница 7: ... ON for all functions It can be turned off or on using the following steps 99 BEEPER OFF TO END 3 0 PROG CODE or iBUTTON 99 BEEPER ON all functions TO END 3 7 PROG CODE or iBUTTON 99 TO CHANGE BEEPER SETTING TO END 3 BEEPER SETTING SEE TABLE PROG CODE or iBUTTON Note that the beeper does not sound during error code flashing no matter what the beeper set ting is BEEPER OFF BEEPER ON It is possible ...

Страница 8: ...2 07 PAGE 8 Building ___________________________ Door Room Number _________________ Lock Type ___________________________ Manager ____________________________ CODE PIN iBUTTON Y N TYPE OF ACCESS NORMAL TOGGLE ETC MANUALLY PROGRAMMED ACCESS CREDENTIAL RECORDING SHEET ...