Ashland EPH30 Скачать руководство пользователя страница 2

2

 

 

 

DANGER

 

Before installation, read the following instructions care-

fully. Failure to follow instruction and safety information 

could cause serious bodily injury, death and/or property 

damage. Each Ashland Pump is individually factory tested 

to ensure proper performance. Closely following these 

instructions will eliminate potential operating problems 

assuring years of trouble-free service.

Most accidents can be avoided by using common sense.
IMPORTANT - Ashland Pump is not responsible for 

losses, injury or death resulting from failure to observe 

these safety precautions, misuse, abuse or misapplica-

tion of pumps or equipment.
 

 

All returned products must  

 

 

 

be cleaned, sanitized, or    

 

 

decontaminated prior to shipment, to  

 

 

insure employees will not be exposed to  

 

 

health hazards in handling said materials.    

 

All applicable laws and regulations shall apply.

   

Bronze/brass fitted pumps may    

   

contain lead levels higher than con-

sidered safe for potable water systems. Government 

agencies have determined that leaded copper alloys 

should not be used in potable water applications. 
   

Installation, wiring, and junction 

   

connections must be in accord-   

ance with the National Electric Code and all applicable 

state and local codes. Requirements may vary depend-

ing on usage and location.

 

   

Installation and servicing is to be    

   

conducted by qualified personnel only.

 

 

Rotating machinery, amputation   

 

 

or severe lacerations can result.   

 

Keep clear of suction and discharge  

 

 

openings. DO NOT insert fingers into pump  

 

with power connected. 

 

 

Always wear eye protection when  

 

 

working on pumps. Do not wear loose 

clothing that may become entangled in moving parts. 
 

 

Pumps build up heat and    

 

 

 

pressure during operation.  

Allow time for pumps to cool before handling or ser-

vicing. 

 

 

Hazardous Voltage can shock,    

 

 

burn or cause death. 

This pump is

  

 not 

intended for use in swimming pools or   

 

water installations where human contact with  

 

pumped fluid is possible. 

 

 

Risk of electrical shock. To  

 

 

 

reduce risk of electrical shock,    

 

always disconnect pump from source  

 

 

before handling.

 Lock out power & tag.

 

 

Effluent Pumps

Model: EPH30

General Safety Information

 

WARNING

 

 

Do Not use these pumps in water  

 

over 145°F. Do not exceed manu-

factures recommended maximum performance, as this 

could cause the motor to overheat.

WARNING

 

   

WARNING

 

WARNING

 

WARNING

 

DANGER

 

DANGER

 

DANGER

 

  

These pumps are NOT to be  

 

 

 

installed in locations classified    

 

as hazardous in accordance with the   

 

 

National Electric Code, ANSI/NFPA 70.

WARNING

 

 

Effluent pumps often handle  

 

 

materials which could cause illness 

or disease. Wear adequate protective clothing when 

working on a used pump or piping. Never enter a ba-

sin after it has been used.

WARNING

 

 

Do not introduce into any sewer,  

 

either directly, or through a kitchen 

waste disposal unit or toilet: Seafood Shells, Aquarium 

Gravel, Cat Litter, Plastic Objects, Sanitary Napkins or 

Tampons, Diapers, Rags, Disposable Wipes or Cloth, 

Medications, Flammable Material, Oil or Grease, 

Strong Chemicals, Gasoline. 

DANGER

 

DANGER

 

 

 

Do not lift, carry or hang pump by  

 

 

the electrical cables. Damage to    

 

the electrical cables can cause shock, burns or  

 

death. Never handle connected power cords  

 

with wet hands. Use appropriate lifting device.

DANGER

 

  

Failure to permanently ground the  

 

 

pump, motor and controls before   

 

connecting to power can cause shock, burns  

 

or death.

DANGER

 

 Make sure lifting handles are securely  

 

fastened each time before lifting.

CAUTION

 

•   Operation against a closed discharge valve will cause

  premature bearing and seal failure on any pump.  
•   Any wiring of pumps should be performed by a  

 

  qualified electrician.
•  Cable should be protected at all times to avoid  

 

  punctures, cuts, bruises, and abrasions-inspect  

 

 frequently.
•  Never handle connected power cords with wet hands.
•   Never let cords or plugs lie in water outside the sump   

 pit.
•   These pumps are offered in a three phase and single  

  phase wiring configuration. Voltages will vary

  according to the application and can be seen in the   

  tables in this manual.

 

Содержание EPH30

Страница 1: ...replacement parts information OPERATION PERFORMANCE SPECIFICATIONS and PARTS MANUAL EPH30 3 10 HP High Head Effluent Pump Effluent Pump Model EPH30 Danger indicates an imminent hazardous situation wh...

Страница 2: ...an contact with pumped fluid is possible Risk of electrical shock To reduce risk of electrical shock always disconnect pump from source before handling Lock out power tag Effluent Pumps Model EPH30 Ge...

Страница 3: ...5 230 1 7 0 3 5 8 75 6 3 9 4 Cast Iron Cast Iron Cast Iron SS Description To pump domestic commercial and light industrial sewage Physical Data DISCHARGE SIZE 1 1 2 NPT IMPELLER TYPE VORTEX CABLE LENG...

Страница 4: ...luent Pumps Model EPH30 Specifications and Performance EPH30 PERFORMANCE CHART Total Lift feet 10 15 20 25 30 34 GPM 45 40 32 24 11 0 HEAD FEET 40 35 30 25 20 15 10 5 0 0 10 20 30 40 50 GALLONS PER MI...

Страница 5: ...e pump Both a check valve and a shut off valve are recommended for each pump The check valve is used to prevent backflow into the sump The shut off valve is used to manually stop system flow during pu...

Страница 6: ...lacing pump on it s side Remove pipe plug from housing Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown If oil is found to be clean and uncontaminated measuring a...

Страница 7: ...and press the upper bearing on the rotor shaft applying force to the inner race of the bearing only In the same manner replace lower bearing 49 onto rotor shaft Seal Plate Lubricate and set o ring in...

Страница 8: ...at control panel before starting disassembly operation Never rely on opening circuit breaker only Operating pump builds up heat and pressure allow time for pump to cool to room temperature Installing...

Страница 9: ...al times by plugging and unplugging cord Check for clogged vent hole in pump case Inlet holes in pump base are clogged Remove pump and clean the openings Vertical pumping distance is too high Reduce d...

Страница 10: ...RING 1 3 091EPH303 SHAFT SEAL 1 4 091EPH304 STATOR ASSY 1 5 091EPH305 SEALING RING 1 6 091EPH306 SCREW 1 7 091EPH307 POWERCORD ASSY 1 8 091EPH308 VOLUTE 1 9 091EPH309 SEAL PLATE 1 10 091EPH310 ROTOR A...

Страница 11: ...ed warranties of merchantability and fitness for a particular purpose No warranties or representations at any time made by any representative of Ashland Pump shall vary or expand the provisions of thi...

Страница 12: ...ferencia Por favor visite nuestra p gina web y el Centro de Productos si desea instrucciones adicionales sobre instalaci n operaci n y piezas de repuesto Advertencia indica una situaci n peligrosa inm...

Страница 13: ...nes de agua potable Las instalaciones cableado y conex iones de empalmes deben realizarse en concordancia con el C digo de Electricidad Nacional y con todos los c digos estatales y locales pertinentes...

Страница 14: ...Hierro forjado EJE DEL MOTOR SST HARDWARE SUS ANILLOS O NBR SELLOS Mec nico simple Carbono cer mico RODAMIENTO SUPERIOR 608 2RZ RODAMIENTO INFERIOR 6202 Numero de modelo Fecha MFG Fase HP SN IMPORTAN...

Страница 15: ...s Modelo EPH30 Especificaciones EPH30 TABLA DE DESEMPE O EPH30 CURVA DE DESEMPE O CABEZA PULGADA GALONES POR MINUTO La elevaci n Total pies 10 15 20 25 30 34 GPM 45 40 32 24 11 0 40 35 30 25 20 15 10...

Страница 16: ...cuentra en la placa de identificaci n y reg strelo en este manual para referencia futura Conexiones el ctricas Apague el interruptor autom tico del circuito antes de enchufar o desenchufar el interrup...

Страница 17: ...e la carcasa Verifique si hay contaminaci n en el aceite utilizando un probador con un rango de 30 kilovoltios Si el aceite est limpio y sin contaminantes m s de 15KV vuelva a llenar la carcasa Si el...

Страница 18: ...eje solo aplique fuerza a la parte interior del rodamiento Reemplace el rodamiento inferior 49 de la misma manera Placa del sello lubrique y coloque el anillo O en la placa del sello Coloque la placa...

Страница 19: ...tes de bajar la bomba al contenedor conecte las l neas el ctricas y arranque el motor El impulsor debe girar en sentido anti horario viendo hacia el impulsor Servicio y reparaci n Importante antes de...

Страница 20: ...si hay obstrucciones en el orificio de ventilaci n en la carcasa La distancia vertical de bombeo es demasiado alta Reduzca la distancia o cambie la descarga de la bomba Los orificios de entrada en la...

Страница 21: ...91EPH303 SELLO DEL EJE 1 4 091EPH304 ESTATOR ASSY 1 5 091EPH305 AILLO DE SELLO 1 6 091EPH306 TORNILLO 1 7 091EPH307 CABLE DE ALIMENTACION 1 8 091EPH308 VOLUTA 1 9 091EPH309 PLACA DE SELLO 1 10 091EPH3...

Страница 22: ...ciada por el n mero de serie del producto No hay otra garant a expl cita o impl cita que cubra su producto Ashland Pump Sin limitar lo anterior Ashland Pump niega espec ficamente las garant as impl ci...

Страница 23: ...e pompe Prenez le temps pour lire attentivement les instructions avant d utiliser ce produit Nous recommandons fortement que vous gardiez ce manuel d instructions dans un endroit s r pour la r f rence...

Страница 24: ...ions et l information de s curit pourrait causer des blessures corporelles graves la mort et ou des dommages mat riels Chaque pompe d Ashland est individuellement test e en usine pour assurer la perfo...

Страница 25: ...CHARGE 1 1 2 NPT TYPE DE L IMPELLEUR Vortex Fonte LONGUEUR DU C BLE 20 Manipulation De Liquide TAILLE DES SOLIDES 3 4 GAMME DE PH ACCEPTABLE 6 8 Temperature STATOR MAXIMAL 120 C Donnees Techniques TY...

Страница 26: ...EPH30 Specifications et Performance EPH30 DIAGRAMME DE LA PERFORMANCE EPH30 COURBE DE LA PERFORMANCE TETE PIEDS GALLONS PAR MINUTE Levage total pieds 10 15 20 25 30 34 GPM 45 40 32 24 11 0 40 35 30 2...

Страница 27: ...d anti retour et une vanne d arr t sont recommand s pour chaque pompe Le clapet d anti retour est utilis pour emp cher le reflux dans le puisard La vanne d arr t est utilis e pour arr ter manuellemen...

Страница 28: ...emps de pomper vers le bas avec la volute ou l eau devraient tre enregis tr es Protection Thermique Le normalement ferm N F sur l e capteur de temp ra ture est noy dans les enroulements du moteur et p...

Страница 29: ...t une force sur la bague int rieure du roulement seulement De la m me mani re remplacez le palier inf rieur 49 sur l arbre de rotor Bo tier d Etanch it Graissez et mettez l anneau d O dans la rainure...

Страница 30: ...panneau La pompe d exploitation accumule la chaleur et la pression laissez le temps la pompe pour refroidir la temp rature ambiante ATTENTION Pompes pour effluent Mod les EPH30 Installation Installati...

Страница 31: ...trous d entr e dans la base de la pompe sont bouch s Retirez la pompe et nettoyez les ouvertures La distance de pompage vertical est trop lev R duisez la distance ou modifiez les raccords de d charge...

Страница 32: ...PH303 JOINT D ARBRE 1 4 091EPH304 ASSEMBLEE DU STATOR 1 5 091EPH305 ANNEAU D ETANCHEITE 1 6 091EPH306 VIS 1 7 091EPH307 CORDON D ALIMENTATION 1 8 091EPH308 VOLUTE 1 9 091EPH309 PLAQUE D ETANCHEITE 1 1...

Страница 33: ...u produit Il n y a aucune autre garantie expresse ou implicite couvrant votre Ashland Pump Sans limiter ce qui pr c de Ashland Pump d cline sp cifiquement les garanties implicites de qualit marchande...

Отзывы: