Tool Trigger Sensitivity
The controller allows the user to set the sensitivity of both the Push-to-Start and the Lever Start (when equipped)
features of the ASG-
SD2500 tool to suit individual user or application preferences. To adjust these settings, tap the ‘Tool
Trig Sen
sitivity’ button on the ‘System’
screen.
On the ‘Trigger Sensitivity’ screen there are two slider bars, one for the Lever, and one for the Push
-to-Start. On each
slider there is the following:
•
Yellow bar
–
shows the minimum trigger reading
•
Red bar
–
shows the maximum trigger reading
•
White bar
–
shows the current trigger reading
•
Green bar - shows the trigger reading threshold
The minimum and maximum readings on each trigger are reset when the controller power is reset. Actuating each
trigger after a power cycle will reset the readings on the sensitivity screen.
To adjust the threshold, use the up and down arrow keys to move the green bar up or down the slider. To test, push the
lever or pull chuck to move the white bar up to the green threshold bar and verify the tool begins to run when desired.