Page 25
Bolt Sequences
The
‘
Bolt Sequences
’
button allows the user to select which parameter(s) will run for a given bolt inside each task. To
assign a parameter to a bolt, select the bolt number (or multiple bolts if they will all have the same parameter(s)) then
tap the button to the right to access the parameter list. Tap the parameter name you wish to choose to select that
parameter for that bolt.
The ‘Number of Bolts’ is assigned in the ‘Setup’ screen on each task, reference the ‘Setup Screen’ section of this
manual for more information.
Multiple bolts can be grouped together and all assigned parameters simultaneously, and they would need to be selected
and ungrouped to program separately again.
Select multiple bolts then the ‘Group’ button to group them together, or
‘Ungroup’ to r
emove the group.
Each bolt can have up to 5 parameters assigned to run in sequence as well. A time delay between parameters may be
programmed in this screen should the application require it. When the bolt count is 50 or less, each bolt can be selected
separately to assign it any of the 8 available parameters on that task. Batch counts of 51 or greater will require all bolts
be assigned the same parameter or sequence of parameters.
When using multiple parameters on a single bolt, only one trigger pull is required for the bolt, but the trigger must be
held until the entire sequence is completed. Releasing the trigger in the middle of the sequence will result in a
‘sequence aborted’ e
rror.
Should one step of a sequence fail during a rundown, the bolt sequence will fail at that point and not proceed to the
next step of the sequence.