User manual for ASIN Aqua
20
2) If You have redox probe
Your Asin Aqua is already installed, connected
to pool water and to chemical agents .
y
Set up the sanitation level on 650 mV
y
Set up the pH value to 7,0
y
Manually adjust the chlorine level in your pool to 0,5 – 1,2 mg/l
by using manualy dosing from ASIN Aqua or hand dosing
of Superchlorination agent directly to pool .
Fine tune
y
Manuallly check
the chlorine level in
the pool water .
y
If the pool’s chlorine
level is to low or
high, adjust the mV
redox settings to fine
tune your system .
Each 0,1 mg/l matches
10 mV of redox.
E XA M P L E:
The pool water chlorine level
is 0,3 mg/l = displayed value is 650 mV.
You want to have 0,5 mg/l.
You have to increase the set up value
of redox from 650 mV to 670 mV.
0,8
0,3
0,4
0,6
0,5
Displayed value
Use aseko tester
650
0,3
24
Wait 24 hours for the probe stabilization.