Item
Maintenance Procedure
Recommendation
pH and Chlor
ine D
osing
Valv
es
Check your valves regularly for
blockages, damaged rubber seals
and the build up of limescale .
Check for damage to the
clear plastic tubes .
In case of very hard water, swop
the clear plastic tube connecting
the pH and chlorine to the valves
every 2 weeks . This prevents
the build up of limescale .
WARNING: Mixing the pH and
chlorine agents is extremely
dangerous . Always wear personal
protective safety equipment,
gloves glasses and mask . After
disconnecting tubes rinse in
clean water before reconnecting .
Change your injection valves
every 2 years for private pool use
or every 1 year for public pools .
# 12005
Chlor
ine and
pH A
gen
t
Regularly check the level .
Chlorine agent decomposes with
time . Replace every 6 months
PH and Chlor
ine
Pumps
Check inside the pumps for
damage . The clear plastic tubes
wear out during operation .
Replace tubes every
12 months . # 12073
Item
Maintenance Procedure
Recommendation
CLF P
robe
Remove your CLF probe from
your ASIN Aqua and clean
off any dust and debris .
Clean your probe with
fresh water and wipe with
a clean soft material .
Check the sensitivity in mV
in CALIBRATION MENU .
If this is at 0,5 mg/l under
10 mV change the electrolyte
or membrane module .
Change the electrolyte
every 6 months . # 12071
Change the membrane module
every 1 years . # 12029
Redo
x P
robe
Remove your Redox probe
from your ASIN Aqua and clean
off any dust and debris .
Clean your probe with
fresh water and wipe with
a clean soft material .
Change your Redox probe
every 1 – 2 years . # 12015
pH P
robe
Remove your pH probe from
your ASIN Aqua and clean
off any dust and debris
Clean your probe with
fresh water and wipe with
a clean soft material .
Change the pH probes
every 1 – 2 years . # 12014