User manual for ASIN Aqua
9
Step 2
Connecting the measuring Water
ASIN Aqua requires connection to the water from your pool . Connect
the supply to your ASIN Aqua after the pump and before the filter .
y
Thread = G 1/4" .
For the water connection to your ASIN Aqua, Aseko provides water
valve with a unique Speedfit connector . To connect, push the clear
plastic tube into the Speedfit connector . To remove the tube from
the connector, push the collet in, and pull on the tube .
WA R N I N G:
Using pliers or cutters damages
your hose and results in a poor fitting .
1.
Cut your clear plastic tube at 90 degree
angle to ensure proper fitting .
y
Use a sharp knife or razor to cut the tubes cleanly
2.
Connect the water input on the left and the water output
on the right . Make sure the water pressure is not more than 1 .5 bar .
3.
The water output from your ASIN Aqua can be connected, on the tubing
before the pump or to the skimmer, the buffer tank or to a drain .
After connecting the water supply, your ASIN Aqua is then set up to take
samples of the water from your pool and analyze them . The analysis allows the
monitoring of chlorine levels and pH levels ensuring your pool hygiene .
WA R N I N G:
Only hand tighten the connections .
Do not use pliers or wrench .
Waste
Waste
Water outlet from probes
must be led into the normal
pressure – into skimmer,
drain or accumulation tank.
Water
supply
Water supply
for the probes (IN)
Water (OUT)
Water valve
Thread 1/4”
Tube 6 x 1
Connection
Water and chemical
6 x 1 clear plastic tube
90°
Water valve
Disconnection