Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
132
Installation
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
Tab. 62
Signals and electrical values for the door intercom interface
Tab. 63
Wiring for door intercom interface 1 (door intercom x.1)
Tab. 64
Wiring for door intercom interface 2 (door intercom x.2)
Function
Signal
Value
Power supply input
AC, AC’
8...14 VAC
Ringing signal input
SON, SON’
5...30 VAC / DC
Connection for two-wire door intercom
Ta, SGND
600
Ω
Microphone signal input
MIC
130 mV (for full output)
Microphone remote supply output
MIC+
approx. 8 VDC
Loudspeaker connection output
LS, SGND
max. 3 W on 4
Ω
Floating contact, "Switch on / off power supply to
door intercom"
TS, TS’
max. 24 VDC, 30 VAC, 1 A
Floating contact, "door opener"
TO, TO’
max. 24 VDC, 30 VAC, 1 A
Signal
Interface x.1
Pin
—
1
—
2
SON’1
3
SON1
4
AC’1
1
AC1
2
TO’1
3
TO1
4
TS’1
1
TS1
2
Tb1 (= SGND1)
3
Ta1
4
SGND1
1
LS1
2
MIC1
3
MIC+1
4
Signal
Interface x.2
16-wire cable
Pin
Stranded ele-
ment
Core colour
MIC+2
1
1
white
MIC2
2
blue
LS2
3
turquoise
SGND2
4
violet