This initialization can be achieved in the following ways:
•
With the HEX rotary switch on the mainboard
•
With AIMS
5. 6. 1. 1
Hardware-induced initialization
1.
Set the HEX rotary switch on the mainboard to "1".
2.
Switch the system off and back on again. The system is restarted.
3.
When a flashing "1" appears on the display, turn the HEX rotary switch to "F".
4.
When an "F" appears, turn the HEX rotary switch to "0"; the PBX resets the cus-
tomer data (Flash EPROM).
5. 6. 1. 2
Software-induced initialization
Carry out an initialization in the AIMS Configuration Manager or in the Fault and
Maintenance Manager under "
Online
"
→
"
Reset PBX
". If the sales channel is also to
be modified, create a new PBX in the AIMS Shell and select a sales channel. Then
under "
Tools
"
→
"
Set/Change Sales Channel
" carry out an initialization using the cor-
responding initialization values.
Note:
To perform a first-start or a sales channel change, either a user account
with the corresponding authorization profile is necessary (see
accounts and authorization profiles", page 163
) or the local, password-
free access must be open (see
"Password-free access", page 169
).
5. 6. 2
Preparing Configuration with AIMS Offline
The complete configuration of a PBX can be created on the PC without access to
the PBX and stored in the database. When this is done, data can be read in from the
Project Manager and supplemented. The prepared configuration can then be up-
loaded to the PBX.
See also:
The procedural steps for configuring an individual system, a private net-
work (PISN) or an Ascotel® IntelliGate® Net (AIN) are described in detail in
AIMS help.