Ascotel® IntelliGate® 2025/2045/2065 as of I7.9
236
Operation and Maintenance
sy
d-
020
4/1.
7
– I7.
9
– 1
2
.2009
The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager:
•
Destination: “
Local PPP
” communication protocol.
•
Call number of the local signal destination (the call number is checked by the
PBX, a warning message will appear if the call number is incorrect)
•
IP address of the PC if the PBX is to connect with the PC via an ISDN gateway.
If the PBX is to connect with the PC without ISDN gateway, the "
IP address
" entry
should remain empty.
•
TCP port number (the initialization value is 1062; if the value is changed in the
SEM, it will have to be altered accordingly on the PBX side.)
•
User name and password of the dial-up networking of the PC or ISDN gateway,
to gain access via the TA or the ISDN gateway to the PC with the SEM.
Configuring a local signal destination on ISDN
The event messages are displayed in PC format.
The "
Local Output Interface
" must be set on "
IP Destination
" in the Fault & Mainte-
nance Manager.
The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager:
•
Destination: PPP via ISDN communication protocol
•
Call number of the local signal destination (the call number is not checked by
the PBX, if the entered call number is incorrect, the PBX will issue the event mes-
sage "
Internal message destination is missing
").
•
IP address of the PC if the PBX is to connect with the PC via an ISDN gateway.
If the PBX is to connect with the PC without ISDN gateway, the "
IP address
" entry
should remain empty.
•
TCP port number (the initialization value is 1062; if the value is changed in the
SEM, it will have to be altered accordingly on the PBX side.)
•
User name and password of the dial-up networking of the PC or ISDN gateway,
to gain access via the TA or the ISDN gateway to the PC with the SEM.