Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 1

e33B

DIGITAL ELECTRONIC 

TEMPERATURE CONTROLLER 

WITH DEFROSTING FUNCTION

OPERATING INSTRUCTIONS

Vr 02 (ENG) - 18/10 - cod.: ISTR-Me33BENG02

ASCON TECNOLOGIC S.r.l.

Viale Indipendenza 56, 27029 - VIGEVANO (PV) ITALY 
Tel.:  +39 0381 69871 - Fax: +39 0381 698730 

http:\\www.ascontecnologic.com

 

[email protected]

PREFACE

D

D

This manual contains the information necessary for 
the product to be installed correctly and also instruc-
tions for its maintenance and use; we therefore recom-
mend that the utmost attention is paid to the following 
instructions and to save it

This document is the exclusive property of Ascon Tecnologic 
S.r.l. which forbids any reproduction and divulgation, even 
partially, of the document, unless expressly authorized.
Ascon Tecnologic S.r.l. reserves the right to make any formal 
or functional changes at any moment and without any notice.
Ascon Tecnologic S.r.l. and its legal representatives do not 
assume any responsibility for any damage to people, things 
or animals deriving from violation, wrong or improper use or 
in any case not in compliance with the instrument features.

D

D

Whenever a failure or a malfunction of the device 
may cause dangerous situations for persons, thing 
or animals, please remember that the plant has to be 
equipped with additional electromechanical devices 
which will guarantee safety.

1.  INSTRUMENT DESCRIPTION

1.1 

General description

The model 

e33B

 is a microprocessor based digital electronic 

temperature controller that is typically used in cooling applica-
tions with 

ON/OFF temperature control

 and 

defrost

 

control

 

at time intervals, by arrival at temperature or by length of time 
of continuous compressor operation through stopping the 
compressor, electric heating or hot gas/cycle inversion.
The controller is equipped with special 

defrost optimization 

functions

 and with other functions that can be used to obtain 

energy savings from the controlled system

.

The instrument has up to 

3 relay outputs

 and up to 

3 NTC 

temperature probes

 inputs 

one of which

 can be 

config-

ured as digital input

.

The instrument has an 

internal buzzer

 for the 

acoustic 

alarms

 signalling and a 

voltage alarm system

 that deacti-

vates the outputs if the 

mains voltage

 is 

too high/low

.

The 

3 outputs

 can be used to 

control the compressor

 or the 

Index

1.  Instrument description ............................................... 1

1.1  General description ........................................................... 1
1.2  Front panel pescription ..................................................... 2

2. Programming ............................................................... 2

2.1  Fast Normal Set Point Programming................................. 2
2.2  Standard mode parameters programming ........................ 3
2.3  Parameter protection using a Password ........................... 3
2.4  Customized mode parameter programming  

(parameters programming level) ....................................... 3

2.5  Reset parameters to default value .................................... 3
2.6  Keyboard lock function ...................................................... 3
2.7  Variables display ............................................................... 4

3.  Usage warnings ........................................................... 4

3.1  Admitted use ..................................................................... 4

4.  Installation warnings ................................................... 4

4.1  Mechanical mounting ........................................................ 4
4.2  Dimensions [mm] .............................................................. 4
4.3  Electrical connections ....................................................... 5

5. Functions ..................................................................... 5

5.1  ON/Stand-by function ........................................................ 5
5.2  Normal, Economic and Turbo operation ............................ 5
5.3  Measure and display configuration ................................... 6
5.4  Digital input configuration .................................................. 7
5.5  Outputs and buzzer configuration ..................................... 7
5.6  Temperature control .......................................................... 8
5.7  Compressor protection function and power-on delay ........ 8
5.8  Defrost control ................................................................... 9
5.9  Evaporator fans control ................................................... 11
5.10  Alarm functions ............................................................... 11
5.11  Function of keys

 

/

 and 

/

 ................................ 12

6. Accessories ............................................................... 13

6.1  Parameters configuration by “A01” .................................. 13

7.  Programmable parameters table .............................. 14
8.  Problems, maintenance and warranty ..................... 17

8.1 Notifications .................................................................... 17
8.2 Cleaning .......................................................................... 17
8.3 Disposal .......................................................................... 17

9.  Warranty and Repairs ............................................... 17
10. Technical data ............................................................ 17

10.1  Electrical characteristics ................................................. 17
10.2  Mechanical characteristics .............................................. 17
10.3  Functional features ......................................................... 18

11. Instrument ordering code ......................................... 18

Содержание e33B

Страница 1: ...ration through stopping the compressor electric heating or hot gas cycle inversion The controller is equipped with special defrost optimization functions and with other functions that can be used to o...

Страница 2: ...Stand by mode this is the only lighted LED In programming mode while the parameter code is displayed the dot indicates the parameter protection level not protected lit up protected flashing and hidde...

Страница 3: ...ial test keeping it pressed for 5 s In this way it is possible to access all the parameters verify and modify the parameter tPP 2 4 Customized mode parameter programming parameters programming level T...

Страница 4: ...d rule must adopt all the necessary protective measures The instrument MUST NOT BE USED in dangerous environ ments flammable or explosive without adequate protections The instrument used with NTC 103A...

Страница 5: ...1 A Out 3 2 1 A 60730 EN UL 5 FUNCTIONS 5 1 ON Stand by function Once powered the instrument can assume 2 different conditions ON Means that the controller uses the control functions STAND BY Means t...

Страница 6: ...always closed 5 3 Measure and display configuration With parameter iuP it is possible to select the tempera ture engineering unit and the desired measure resolution C0 C 1 C1 C 0 1 F0 F 1 F1 F 0 1 The...

Страница 7: ...that is NO in normal operation then closed during the alarm AL To control an alarm that cannot be silenced through a contact that is NO in normal operation then closed during the alarm An To control a...

Страница 8: ...s automatic switching between the three Normal Eco Turbo modes described at the paragraph Operating modes The time protections described in the next paragraph PP1 PP2 PP3 always work on the ot configu...

Страница 9: ...a chines in which is required the maximum evaporator efficiency at each compressor cycle To enable automatic defrost at intervals after setting the ddC parameter as desired between rt ct or cS with th...

Страница 10: ...related to the EP probe under which defrosts are possible Therefore in the indicated modes if the temperature meas ured by the EP probe is higher than the one set at parameter dtS and also dtE defros...

Страница 11: ...emperature alarms Hi and Lo External alarm AL Door open oP The alarm functions acts on LED on the internal buzzer if present and configured by the obu parameter and on the desired output if configured...

Страница 12: ...The instrument can signal an alarm external to the instrument using the digital input setting iFi 4 or 5 The instrument signals the alarm turning ON the alarm LED and display ing AL label alternated...

Страница 13: ...f some instruments which need to have the same parameters con figuration or to keep a copy of the parameters settings of an instrument and allow its rapid retransmission The same device allows to conn...

Страница 14: ...ck 3 Open Door with Fan and Output Lock 4 External Alarm 5 External alarm with control output disabling 6 Normal Eco select 7 On Stand by select 8 Start a Turbo cycle 2 15 iti Digital Input Delay oF D...

Страница 15: ...n disabled 1 59 s 1 99 min 5 42 FtF Fan time deactivation with ot output compressor OFF oF Function disabled 1 59 s 1 99 min oF 43 FFL High temperature fan deactivation 99 9 999 C F 10 0 44 FLF Low te...

Страница 16: ...otu Time relative to auxiliary output oF Function disabled 1 59 s 1 99 min oF 67 tUF Key Function oF No function 1 Eco Mode direct selection turn OFF the showcase light if configured 2 Switch ON Swit...

Страница 17: ...faults found without any fees or charge for Ascon Tecnologic except in the event of alternative agreements 10 TECHNICAL DATA 10 1 Electrical characteristics Power supply 230 VAC 115 VAC 12 VAC VDC 10...

Страница 18: ...C 103AT11 11 INSTRUMENT ORDERING CODE MODEL e33B Instrument with mechanical keyboard a POWER SUPPLY D 230 VAC C 115 VAC F 12 VAC VDC b OUTPUT 1 OUT 1 H Out1 Relay SPST NO 16A AC1 for resistive loads R...

Страница 19: ...Ascon Tecnologic e33B OPERATING INSTRUCTIONS PAG 19...