Programming and Installation Manual
Care Phone
<Alarm Receipt> used to activate the relay when an alarm has been sent to an
alarm receiver and has been received by the alarm receiver.
<System Warning> used to activate the relay when the function "System
Warning' indicates that something is wrong. For more information about the
"System Warning", see below.
>Activation time<
Determines how long the exit shall be activated.
External input:
>External 1< and >External 2<
<Normal open> The external input is activated once closed.
<Normal closed> The external input is activated once opened.
<Presence> The external input is activated when there is a connection and sends
a presence indication to the alarm receiver.
<Ready> The external input is activated when there is a connection and sends a
ready indication to the alarm receiver.
<Presence/Ready> When closed a presence indication is sent. When the next
closed is indicated a ready indication is sent.
<Red button> In this mode the external input has the same function as the red
top button.
<Green button> In this mode the external input has the same function as the
green top button.
<Grey button> In this mode the external input has the same function as the grey
top button.
Other
> System Warning<
>Activation< >Warn. sources<
Once system warning is activated, the LEDs flash and/or a sound emanates from
the speaker. Choose <Visual> <Acoustic> <Both> or <Not activated>. The
system warning indicates low battery, mains failure or that the line has
disappeared. By pressing the green reset button the audible warning is stopped.
The acoustic/visual warning can be programmed individually directly or
independently via the hand terminal. These signals only appear when Analog
Care Phone / GSM Care Phone is in normal mode. See light signal table in
Section 1.5.
Under >Warn. sources< you can define which of the following warnings the
system warning should indicate: >Line failure<, >Mains failure<, >Acc failure<
and >GSM failure<. (The last-mentioned is only available in Careline GSM.) For
example should the line failure warning be deactivated when you send all the
alarms via GSM and no phone line is connected.
>LED indicators<
In this menu you can set the >Level< of the LEDs on the top of the Care Phone.
This applies to both the LEDS in the red alarm button and the LEDs that signal