2-4
Installing an EN/SC Adapter
Setting link integrity on the Mini EN/SC Adapter
With a 10BaseT-compliant network, the Link Integrity switch must be
set ON (default) on the Mini EN/SC Adapter. The switch is on the
bottom of the adapter. See Figure 2-3.
If your Twisted Pair Ethernet network is not 10BaseT-compliant, the
Link Integrity switch must be OFF.
❖
Note: When Link Integrity is OFF, the 10BaseT port is
selected by default and auto-sensing for the 10BaseT and
Thin ports on the Mini EN/SC Adapter is disabled.
❖
The Link Integrity switch is not provided on the Micro EN/SC Adapter.
Setting the SCSI address on the Mini EN/SC Adapter
When you connect a SCSI device to a Macintosh, the device must
have a unique SCSI address between 1 and 6; 0 is usually reserved
for the Macintosh internal hard drive.
The SCSI address on the Micro EN/SC Adapter is set to 6 and cannot
be changed.
Use the rotary switch on the bottom of the Mini EN/SC Adapter to set
the SCSI address. See Figure 2-3.
Figure 2-3
Mini EN/SC Adapter switches
SCSI ID
LINK INTEGRITY
TERMINATION
SCSI address
selector
Link Integrity
SCSI Terminatio
Ethernet address
switch
switch
ENSC Ch 2 Page 4 Monday, August 26, 1996 2:50 PM