Specifications
|
79
Do not use a damaged or non-recommended power cord with your switch. Using such power cords voids the switch
and power supply warranty. It can also cause serious electrical problems, including injury or death to personnel,
and damage to the switch and other property. If you cannot verify that you have a power cord approved for use
with your switch model, contact your authorized Aruba dealer or sales representative for assistance.
Environmental Specifications
Operating temperature
-40°C to 60°C, 0m/s (-40°F to 140°F, 0 LFM) sealed enclosure
-40°C to 70°C, 0.2m/s (-40°F to 158°F, 40 LFM) vented enclosure
-34°C to 75°C, 1m/s (-29.2°F to 167°F, 200 LFM) fan equipped enclosure
Operating relative humidity
5% to 95% (non-condensing)
Non-operating temperature
-40°C to 85°C (-40°F to 185°F ) up to 15000 ft
Max operating altitude
up to 4.2 km (13800 ft)
Max non-operating altitude
4.6 km (15000 ft)
Degree of protection
IP30
RoHS
EN 63000: 2018
Safety and Regulatory Information
For important safety, environmental, and regulatory information, see Safety and Compliance Information for
Server, Storage, Power, Networking, and Rack Products, available at
http://www.hpe.com/support/Safety-
Safety-EU
EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013
EN 62368-1, Ed.2:2014
Safety-Worldwide
IEC 60950-1:2005 Ed.2 + Am 1:2009 + A2:2013
IEC 62368-1:2014
EN/IEC 60825-1:2014 Class 1
UL/IEC 61010-2-201
GB 4943.1:2011
CNS 14336-1
K 60950-1