![artisan PEFT Junior Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/artisan/peft-junior/peft-junior_user-manual_2978433035.webp)
26
EFT/ Burst Generator PEFT Junior
5.4.2 Installation for three phase testing
The following installation is described in the standard.
L3
N
PE
Reference Ground
connector
EUT
EFT/B Generator
Cc
Cc
Cc
Cc=33nF
L1
L2
Cc
Cc
Fig.
5.4.2.a
To comply with this tests requirements, it is necessary to use a three phase coupling filter type
FP-EFT 32.1. This filter has the same advantages as the single phase integrated filter, that is
automatic control of the coupling paths from the PEFT Junior menu.
A system comprising a PEFT Junior and a filter FP-EFT 32.1 enables testing to all levels as for
the single phase filter.
FILTER
OPEN
BY-PASS
INPUT
SAFETY SWITCH
32A 690V
COUPLING
HAEFELY
FP-EF T 32.1
POWER
ON/OFF
L1
L2
L3
N
PE
DIRECT OUTPUT
INPUT
HAEFELY
CONTROL UNIT
HAEFELY
PEFT.1
LINE INPUT
LINE OUTPUT
GND
EUT
FP-EFT 32.1
PEFT Junior
Fig. 5.4.2.b