PCIE Software
SharpStreamer™ Pro Mini PCIE-7210-1 Installation and Use (6806800U78A
)
68
5.3.3.1.2 T1 - Host Server Resets in BIOS
The PCIE-7210-1 card is qualified on third party RMS like Dell R730 and Dell R430 with CentOS
7.X. These servers will throw an error in BIOS and would continuously reset till the card is
configured. This sequence happens till the Quark SoC is up and configures the PEX9716
appropriately. Once PEX is configured the host transits to sequence T3.
5.3.3.2
Power Down Sequence
In fabric mode, the Skylake-H and Host subsystems are dependent on Quark subsystems.
Hence the PLX manager (Quark) should always be running as along as any host OS is running.
If this dependency is not met, then Linux Kernel on server CPU/Skylake-H will crash/panic. As a
consequence the entire system will become unuseable and would need a complete power
cycle. In order to avoid this, all host OSes should be powered off before powering off the Quark
CPU. However, host server provides power to card’s (Quark) which means host server should
be powered off at the end.
Following table describes the power down timing sequence.
In HP RMS, the host server hangs at T1. Customers can work with server vendors
to change the BIOS accordingly.
Hence it is recommended that customers use the validated RMS.
Table 5-4 Power Down Timing Sequence
TIME
SEVER
QUARK
(CardX)
SKYLAKE
(CardX)
QUARK
[CardY]
SKYLAKE
[CardY]
T
0
Linux power off
Linux power off
T
1
Linux reboot
T
2
Keep in BIOS
T
3
Keep in BIOS
Linux power off
Linux power off
T
4
Power off by
removing the
power directly
Содержание 6806800U78A
Страница 1: ...SharpStreamer Pro Mini PCIE 7210 1 Installation and Use P N 6806800U78A December 2017 ...
Страница 8: ...SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A 8 List of Tables ...
Страница 10: ...SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A 10 List of Figures ...
Страница 16: ...SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A About this Manual 16 About this Manual ...
Страница 20: ...SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A Safety Notes 20 ...
Страница 24: ...SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A Sicherheitshinweise 24 ...
Страница 30: ...Introduction SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A 30 ...
Страница 38: ...Hardware Preparation and Installation SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A 38 ...
Страница 80: ...PCIE Software SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A 80 ...
Страница 92: ...Related Documentation SharpStreamer Pro Mini PCIE 7210 1 Installation and Use 6806800U78A 92 ...
Страница 93: ......