Arjohuntleigh Maxi Move KMC*U Series Скачать руководство пользователя страница 1

Maxi Move Scale

Technical Manual

...with people in mind

001-25013-EN Rev 

   •  

/201

Содержание Maxi Move KMC*U Series

Страница 1: ...Maxi Move Scale Technical Manual with people in mind 001 25013 EN Rev 201 ...

Страница 2: ...joHuntleigh group of companies ArjoHuntleigh 2014 As our policy is one of continuous improvement we reserve the right to modify designs without prior notice The content of this publication may not be copied either whole or in part without the consent of ArjoHuntleigh ...

Страница 3: ...erification 20 For Verified Scales 20 For Non Verified Scales 20 SP4 Maxi Move Communication Tool 21 Installing the drivers 22 SP5 Scale Calibration 25 Verified Scale 25 Using the Application 26 SP6 Scale Replacement 31 Verified Scale 31 Non Verified Scale 31 SP7 Scale Installation on a Non Scale Unit 32 Ordering Kits 32 Verified Scale CE Country 32 Non Verified Scale Outside the European Communit...

Страница 4: ...ity counter Each time an operation changes the value of the calibration or of the gravity code the corresponding counter is automatically incremented without any possibility of being reset On the scale marking label there are actually two labels a calibration label and a gravity label These labels are applied at the factory and or at the distribution centers and have the same value of the calibrat...

Страница 5: ...the software seal system as do verified scales Also the verification and calibration can be carried out by an ARJO technician The scale marking labels for these units are located on the mast behind the battery pack see Fig 2 Fig 2 The tilt sensor is disabled for non verified scales and the units of measurement can be set either to kg or lb Note For scale operation instructions see the scale sectio...

Страница 6: ...4 To return to normal scale function press the exit button Fig 6 Compare both values to the ones on the scale marking label If there is a difference this means an unauthorized change has been performed on the calibration and or the gravitational code The scale is not longer valid and must be verified by a notified body A new label must also be applied to match the values stored in the counter with...

Страница 7: ...the main switch and hold the buttons down until a beep is heard 2 Adjust the gravity code After 10 seconds the display will indicate the gravity code with which the unit was initially verified or the code the unit is presently configured with e g 00 Use the list of codes by country found in the gravity adjustment table page 17 to identify which code to configure the instrument with To modify the d...

Страница 8: ... should be used or a location is undetermined in the gravity adjustment table use the Google Earth application to determine the latitude and altitude Get on the internet at the following address http www google com intl en earth download ge Locate and click the Download Google Earth 6 button or newer version if available After the download is completed install the application on your computer foll...

Страница 9: ...s and Meters Kilometers then click OK In the Search field enter the information about the location of the final customer name of the city and the country then click the magnifier button to search the location Google Earth will search and display the location in the center of the screen ...

Страница 10: ... the longitude long and the elevation elev Note Do not confuse elevation with the Altitude mentioned in the right bottom corner This mention is referring to the camera position When code 99 has been confirmed the display will show the elevation on the first line and the latitude on the second line To configure the elevation and latitude press the following button The display will then show the ele...

Страница 11: ...levation use the following buttons elevation is shown in meters Confirm the elevation by pressing the following button The display will now display the latitude Move the cursor to the left Increase value Decrease value Move the cursor to the right CONFIRM button ...

Страница 12: ...n The display will show the elevation on the first line and the latitude on the second line Confirm the values using the following buttons For code 99 the configuration is complete WAIT 5 SECONDS and then shut off the instrument Move the cursor to the left Increase value Decrease value Move the cursor to the right CONFIRM button CONFIRM button Elevation m Latitude ...

Страница 13: ...enu to get the value of the Gravity Counter see Counter Verification section Apply a label corresponding to this value to the CE Marking label For Austria Germany Switzerland and Sweden apply a new gravity zone label over the scale marking label as specified in the Gravity Adjustment Table on page 17 if necessary ...

Страница 14: ... apply a new label 001 00536 over the scale marking label if necessary Write down the year of validity year of apposition 1 year Punch or circle with a black permanent pen the month of apposition NOTE Have the change verified and approved by a notified body ...

Страница 15: ...93 m s2 20 gR 9 795135 m s2 9 793502 m s2 9 796768 m s2 Italy MFG CODE GRAVITY ZONE 40 gR 9 80655 m s2 41 gR 9 80237 m s2 42 gR 9 80129 m s2 43 gR 9 79819 m s2 44 gR 9 80375 m s2 Luxemburg MFG CODE GRAVITY ZONE 47 gR 9 82308 U K MFG CODE GRAVITY ZONE 34 50 53 0 200 35 53 56 0 200 36 56 59 0 200 Ireland MFG CODE GRAVITY ZONE 38 gR 9 814 Iceland MFG CODE GRAVITY ZONE 39 gR 9 82308 Netherlands MFG CO...

Страница 16: ... CODE GRAVITY ZONE 55 43 5 46 0 300 Slovakia MFG CODE GRAVITY ZONE 56 48 49 5 100 700 Czech Republic MFG CODE GRAVITY ZONE 54 48 5 50 5 100 500 Poland MFG CODE GRAVITY ZONE 53 52 54 5 0 300 Hungary MFG CODE GRAVITY ZONE 37 gR 9 807796 m s2 Latvia MFG CODE GRAVITY ZONE 45 55 5 58 0 300 Lithuania MFG CODE GRAVITY ZONE 46 53 5 0 300 Estonia MFG CODE GRAVITY ZONE 21 gR 9 817823 m s2 Sweden MFG CODE GR...

Страница 17: ...00 to 6999 08 4000 4999 09 Canada J1X 5Y2 00 Cyprus N A 10 Czech Republic N A 54 Denmark N A 17 Estonia N A 21 France 02 08 59 60 62 76 80 22 10 14 22 27 28 29 35 50 51 53 54 55 57 61 75 77 78 91 92 93 94 95 23 37 41 44 45 49 56 79 85 86 24 16 17 24 33 25 32 40 47 82 26 13 34 27 03 23 69 87 28 18 36 58 71 29 21 70 90 30 52 88 31 68 89 32 67 33 Germany N A 05 001 25077 Hungary N A 37 Iceland N A 39...

Страница 18: ... N A 52 Norway 0000 to 5999 6700 to 6999 12 6000 to 6699 7000 to 8999 50 9000 to 9999 51 Poland N A 53 Romania N A 55 Slovakia N A 56 Slovenia N A 06 Spain 02 03 04 05 06 07 09 10 11 12 13 14 16 19 21 23 24 28 29 30 34 37 40 41 42 44 45 46 47 49 18 01 08 15 17 20 22 25 26 27 31 32 33 36 39 43 48 50 19 18 35 38 20 Sweden 00000 to 82999 except for 82046 12 001 25070 82046 83000 to 99999 15 001 25071...

Страница 19: ...1 001 25072 Zone 2 www metas ch SwissGravityZones 02 001 25073 Zone 3 www metas ch SwissGravityZones 03 001 25074 Zone 4 www metas ch SwissGravityZones 04 001 25075 KY FK PA PH DD AB IV KW 36 UK centre UK south BB BD BL BT CA CH CW DG DH DL DN EH FY G HD HG HU HX KA L LA LN LS M ML NE OL PR S SK SR TD TS WA WF WN YO 35 AL BA BH BN BR BS CB CF CM CO CR CT DA DE DT E EC EN EX GL GU HA HP IG IP KT LD...

Страница 20: ...olvement of a notified body Note ARJO technicians can perform a verification to check if the scale meets all the needed requirements but this has no legal value in Europe Only an authorized notified body can make the verification and provide a mark of approval However it is recommended that ARJO technicians perform a verification after the calibration to be sure the calibration is correct before t...

Страница 21: ...our different country adapters the communication tool with a USB cable 005 25000 a cable to connect the communication tool and the load cell on the Maxi Move a sheet of gravity calibration labels 001 25061 which can be found behind the top foam layer in the case cover Fig 10 Note This tool is to be used with the Maxi Move produced by BHM Medical in Canada Model KMC QQQ Note The communication tool ...

Страница 22: ...nication Tool Installing the drivers To install the application you must start MMCalibSetup exe provided on a CD Rom or via FTP access at http files bhm medical com misc MMCalibSetup exe Once started the following box will appear on the screen ...

Страница 23: ...s SP4 Maxi Move Communication Tool Click Next to get to the following screen Once at this screen plug in your Maxi Move Communication tool and check the I accept the terms of the Licence Agreement box before clicking Next ...

Страница 24: ...tion is complete Initiate the installation It may take a while if the Net Framework is not installed While the installation is proceeding you may see two pop ups indicating that a driver is trying to be installed You MUST click Continue Anyway in order to allow the driver to be installed Once the installation process is completed make sure the Maxi Move Communication tool switch is set to OFF befo...

Страница 25: ...on Verified Scale 1 Attach a spreader bar and a sling suitable to hold the calibration weight to the Maxi Move 2 Remove the two bottom screws of the top cover and take off the top cover 3 Disconnect the load cell from the floor lift and connect it directly to the tool kit see Fig 11 and Fig 12 Fig 11 Fig 12 Note Prior to the scale calibration make sure that the gravity code is set according to the...

Страница 26: ...axi Move communication tool switch is set to OFF The following screen will appear 6 Once ready click Connect The application will try to find the COM port to which the tool is connected If not found the installation was either unsuccessful or the device was not plugged in correctly If the COM port is found it will try to connect to it and the following message will pop up ...

Страница 27: ...mmunication tool switch to ON and then click OK The application will try to communicate with the scale If successful the version of the scale firmware will show up as a result If not an error has occurred and you will have to restart the connection procedure Successful connection ...

Страница 28: ...gle of the scale Constantly get information Same as Get Information but information is updated each second for the weight and each 5 seconds for the angle You must click the button again to stop getting information and to be able to perform other actions Calibrate This will calibrate the scale The steps involved in calibrating the scale are as follows 8 Click the Calibrate button 9 Click Yes to co...

Страница 29: ...ight specified in the support on the unit and click Ok 13 You will receive a confirmation message that the scale is correctly calibrated The calibration is now complete If anything goes wrong in the calibration an error message will pop up and the whole connection process will need to be restarted If you fail to calibrate more that 4 5 times it is likely that there is a problem with the connection...

Страница 30: ...all weight from the sling and press the power button to turn the unit on 17 Verify the calibration see SP3 Scale Verification section 18 If the calibration is beyond the tolerance range repeat the calibration procedure starting from step 1 19 If calibration is correct enter the Counter menu see SP1 Counter Verification section and note the calibration counter value Apply a new calibration label on...

Страница 31: ...e the serial number of the Maxi Move on the scale marking label next to the letters SN Keep the provided logbook 001 25078 with the customer s current logbook Perform a scale verification see SP4 If the calibration is within the correct tolerance range enter the counter menu see SP1 Counter Verification procedure and note the value of the calibration counter Apply a new calibration label with the ...

Страница 32: ...e scale logo to the Maxi Move top cover see callout 3 4 Replace the model label with the one supplied in the upgrade kit Note In kit 700 25335 two different label models are supplied for KMCSXN and KMCLXN Use the label corresponding to the model of the unit being upgraded and discard the MAXI MOVE MODEL SERVICE KIT NUMBER SERVICE KIT DESCRIPTION KMCQXN in a non CE country 700 25340 Maxi Move stan ...

Страница 33: ... considered as a new unit and must pass through a complete EC verification by an authorized notified body This certifies that the load cell was installed correctly and complies with the previous type approval issue for the Maxi Move scale If the unit passes the EC verification the notified body will emit a certificate of conformity This document must remain in Arjo s possession The CE declaration ...

Страница 34: ...he handset see Fig 15 callout 2 3 Apply the scale logo to the Maxi Move top cover see Fig 15 callout 3 4 Replace the model label with the one supplied in the upgrade kit Note In kit 700 25340 two different label models are supplied for KMCSXN and KMCLXN Use the label corresponding to the model of the unit being upgraded and discard the other see Fig 15 callout 4 Fig 15 Apply behind battery ...

Страница 35: ...ffice G005 Nucleotide Complex Dubai Biotechnology Research Park P O Box 214742 Dubai United Arab Emirates Tel 971 0 4 447 0942 E mail Info ME getinge com NEDERLAND ArjoHuntleigh Nederland BV Biezenwei 21 4004 MB TIEL Postbus 6116 4000 HC TIEL Tel 31 0 344 64 08 00 Fax 31 0 344 64 08 85 E mail info nl arjohuntleigh com NEW ZEALAND ArjoHuntleigh Ltd 41 Vestey Drive Mount Wellington NZ AUCKLAND 1060 ...

Страница 36: ...fective everyday care early mobilisation safe patient handling venous thromboembolism prevention pressure injury prevention hygiene routines bariatric care and diagnostics With extensive know ledge and experience we strive to improve efficiency and ensure a safer and dignified environment for caregivers and their patients ArjoHuntleigh AB Hans Michelsensgatan 10 211 20 Malmö Sweden www arjohuntleigh...

Отзывы: