25
Legend:
A
-
ON/OFF button
B
-
Multifunction display
C
-
Reset button
D
-
Green LED (Indicates burner on)
E
-
Comfort function LED (yellow)
F
-
Red LED (indicates lockout)
G
-
COMFORT button
H
-
Central Heating temperature adjustment
I
-
Programming key +
L
-
Programming key -
M
-
Menu button
N
-
Domestic Hot Water temperature adjustment
O
-
EEPROM key
CN1 =
FAN
1:
Start of coil (black)
2:
End of coil (brown)
3:
“Hall” sensor power supply 12V (red)
4:
“Hall” sensor input (white)
5:
“Hall” sensor neutral (blue)
6:
Not used
CN2 = FLAME SENSOR
CN3 = Earth
CN4 =
POWER SUPPLY
1:
Live (brown)
2:
Neutral (blue)
CN5 =
EQUIPMENT
CONNECTIONS
1:
Gas valve neutral (blue)
2:
Gas valve live (brown)
3:
Not used
4:
Pump
(V1) live (red)
5:
Pump
(V2) live (black)
6:
Pump
(ON/OFF) live (
brown
)
7:
Pump
neutral
(blue)
8:
3-way valve (C.H.) (red/black)
9:
3-way valve (D.H.W.)
(brown)
10:
3-way valve
Neutral (blue)
11: Spark generator Neutral (black)
12: Spark generator live (black)
CN6 = INTERFACE PCB
(OPTIONAL - see Section 2.12)
Accessories:
External sensor
Remote Control CLIMA MANAGER
Secondary outlet
(
see Section. 2.12
)
CN7 = DISPLAY
1: Power 5V
2: Display return
3: Display transmission
4: Earth
CN8 = SENSOR CONNECTOR
1: Central Heating flow sensor (white)
2: Central Heating return sensor (white)
3: Not used
4: DHW flow switch (grey)
5: DHW sensor (grey)
6: Not used
7: Not used
8: DHW flow switch earth (grey)
9: DHW sensor earth (grey)
10: C.H. flow sensor earth (white)
11: C.H. return sensor earth (white)
12: Not used
CN9 = ROOM THERMOSTAT
(OPTIONAL - see Section 2.12)
CN10 = UNDERFLOOR HEATING
SAFETY THERMOSTAT
(OPTIONAL - Section 2.12)
CN11 = TIME CLOCK
(see Section 2.12)
CN12 = SENSOR CONNECTOR
1: Not
used
2: Not used
3: Low water pressure switch
4: Low water pressure switch earth
5: Overheat thermostat
6: Overheat thermostat