2.3.
O
VERALL
D
IMENSIONS
In order to allow access to the interior of the boiler for maintenance
purposes, the boiler must be installed in compliance with the
clearance requirements indicated in the diagram below.
2.4.
MINIMUM CLEARANCES
L
EGEND
:
A
= Central Heating Flow (3/4”) (22mm Copper Tail)
B
= Domestic Hot Water Outlet (1/2”) (15 mm Copper Tail)
C
= Gas Inlet (3/4”) ( 22mm Copper Tail)
D
= Domestic Cold Water Inlet (1/2”) (15mm Copper Tail)
E
= Central Heating Return (3/4”) (22mm Copper Tail)
SV outlet
= 1/2” Female BSP (Not Shown)
785
310
450
F
IG
. 2.0
93
65
450
67
67
65
93
143
100
120
750
35
5
45
50
water
gas
310
323
225
225
130 130
F
F
IG
. 2.1
F
IG
. 2.2
After removing the boiler from its packaging, remove the
template from the separate box containing the connection kit.
N
OTE
: Pay particular attention to any test water that may spill
from the appliance.
Place the template in the position the appliance is to be
mounted and after ensuring it is hanging squarely, use it to mark
the holes for the hanging bracket, connection kit and flue pipe(s)
NB:
For further information relating to the flue installation please
refer to Section 2.9 F
LUE
C
ONNECTION
. (If the appliance is to be
fitted on a wall of combustible material, the wall
must
be
protected by a sheet of fireproof material).
If the appliance is to be fitted into a timber framed building,
guidance should be sought from the Institute of Gas Engineers
document R
EF
: IGE/UP/7.
2.5.1.
Drill the wall and plug using those supplied with the
connections kit, position the hanging bracket and
secure with the wall screws supplied, assemble the
connection kit and secure to the wall.
N
OTE
:
It is highly
recommended that a spirit level be used to position the
appliance to ensure that it is perfectly level.
2.5.2.
Position the appliance on the hanging bracket and
connect the connection kit to the boiler connections.
(see also Sections 2.7 Gas Connections, 2.8 Water
Connections & F
IG
. 2.4).
For safety purposes, have a competent person carefully check
the electrical system in the property, as the manufacturer will not
be held liable for damage caused by the failure to earth the
appliance properly or by anomalies in the supply of power. Make
sure that the residential electrical system is adequate for the
maximum power absorbed by the unit, which is indicated on the
rating plate. In addition, check that the section of cabling is
appropriate for the power absorbed by the boiler.
2.5.
M
OUNTING THE
A
PPLIANCE