![Ariston ACO 35 MFFI Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/ariston/aco-35-mffi/aco-35-mffi_installation-and-servicing-instructions_2970933042.webp)
42
The soft light can be adjusted between the maximum power
(shown on the display as "99", i.e. 100%) and minimum power
(shown on the display as "00", i.e. 1%). The boiler is factory set to
a value which is suitable for ignition with any type of gas.
The value set (expressed as a percentage) can be displayed and
modified as illustrated in paragraph 3.6.1 (parameter 1).
The ignition delay can be adjusted to between 0 and 7 minutes.
The delay is factory set to 2 minutes.
The value set can be displayed and modified as illustrated in
paragraph 3.6.1 (parameter 3).
3.6.4 I
GNITION
D
ELAY
A
DJUSTMENT
3.6.5 A
DJUSTING THE
M
AXIMUM
H
EATING
P
OWER
3.6.6 S
OFT
L
IGHT
A
DJUSTMENT
The maximum heating power can be adjusted between the
maximum power allowed by the boiler (29.4kW) and the minimum
power (6.5 kW) indicated in the graph. The value is factory set to
70% of the maximum power.
The value set (expressed as a percentage) can be displayed and
modified as described in paragraph 3.6.1 (parameter 2) using the
graph on Page 35.
3.7 C
HANGING THE
T
YPE OF
G
AS
The boiler operation can be changed over from methane gas
(G20) to Liquid Gas (G31) or vice versa, an operation that must
be performed by a CORGI registered Gas Engineer.
To change the type of gas it is necessary to proceed as follows:
1.
Before starting ensure both the gas and electrical supplies
to the boiler are isolated and the boiler is cool.
2. Remove the casing as indicated in Section 3.2.
3. Remove the silencer
4. Disconnect the electrical connection of gas valve and fan.
5. Remove the three torx screws of the air gas connections
(see Fig. 3.32) and loosen the nut under the gas valve
(see Fig. 3.33)
5. Remove all the mixer/fan/gas valve group (see Fig. 3.34)
6. Unscrew the four torx screws and disconnect the gas valve (see
Fig. 3.35).
7. Insert the diaphram into the gas valve (see Fig. 3.36)
8. Reassemble in reverse order.
9. Replace the gas label.