Important!!
The parameters P5 and P6 are only enabled when the
outdoor sensor is activated (Parameter P - page 37-
38).
To return to the normal display, press the menu button .
Parameter
Function
Range
Factory setting
r
selects low temperature systems
or standard systems
0 0
(Low temperature)
0 1
(Standard System)
0 1
p 9
Temperature regulation controlled by
external sensor
9 0
(Disabled)
9 1
(Enabled)
9 0
p 6
Correction of heat curve translation
from
-20
to
+ 2 0
P 5
Curve incline
from
0_1
to
5 _ 0
0 _ 9
t
Test Function
A
Bus Address (Do not modify)
b 0
Set-point second heating zone
from
2 5
to
8 2
7 5
b 1
GSM value (Do not modify)
b 2
Heating delay after commutation in
DHW (from 0 to 30 minutes)
from
00
to
3 0
(step: 1 minute)
0 0
b 3
Post-ventilation in Heating mode
0
(Disabled)
1
(Enabled)
1
b 4
NOT USED
b 5
NOT USED
b 7
NOT USED
b 8
NOT USED