F
IG
. 7.20
7.3.6. R
EMOVING THE
H
EAT
E
XCHANGER
1.
Drain the boiler;
2.
Remove the air/gas assembly
see section 7.3.1
;
3.
Remove the electrodes
see section 7.3.3 - 7.3.4
;
4.
Remove the condensate trap tube
see section 7.3.7
;
5.
Unplug the C.H. return and flow temperature probes
and the overheat thermostat (F
IG
. 7.18);
6.
Unplug the pipe clips (F
IG
. 7.18);
7.
Loosen the nut
“I”
and remove the pipe (F
IG
. 7.19 - 7.20);
8.
Loosen the nut
“J”
and remove the pipe (F
IG
. 7.21 - 7.22);
9.
Loosen the nuts
“K”
and remove the exchanger
(F
IG
. 7.23 - 7.24).
F
IG
. 7.18
F
IG
. 7.22
F
IG
. 7.23
F
IG
. 7.21
F
IG
. 7.19
J
I
ATTENTION!!
When removing the heat exchanger, ensure that
no water can enter the electrical box containing
the PCB!
K
K
K