62
7.5.6. R
EMOVING THE
P
UMP
1.
Unplug the electrical connection “A7” (F
IG
. 7.48);
2.
Unscrew the four screws “A8” (F
IG
. 7.49);
3.
Remove the pump (F
IG
. 7.50).
F
IG
. 7.48
F
IG
. 7.49
A7
A8
A8
A8
A8
A6
7.5.5. R
EMOVING THE
D.H.W. F
LOW
S
WITCH
(MFFI
ONLY
)
1.
Unplug the electrical connector;
2.
Unscrew the four screws “A6” (F
IG
. 7.46);
3.
Remove the D.H.W. flow switch (F
IG
. 7.47).
F
IG
. 7.46
F
IG
. 7.47
A5
F
IG
. 7.44
7.5.4. R
EMOVING THE
D
IVERTER
V
ALVE
A
CTUATOR
1.
Unplug the electrical connector “A4” (F
IG
. 7.44);
2.
Release the retaining clip “A5” and remove the diverter
valve actuator (F
IG
. 7.45).
F
IG
. 7.45
A4
Содержание ACO 27 MFFI