The exhaust gas ducts must not be in contact with or close to
inflammable material and must not pass through building
structures or walls made of inflammable material.
When replacing an old appliance, the flue system must be
changed.
Important
Ensure that the flue is not blocked.
Ensure that the flue is supported and
assembled in accordance with these
instructions.
2.9.1 F
ITTING THE
C
OAXIAL
F
LUE
(Ø 60 / 100 H
ORIZONTAL
)
Installation without extension
Installation with extension
Fig. 2.10
Fig. 2.11
118
Level
Level
C
ONTENTS
:
1
X
S
ILICONE
O-R
ING
(60mm)
1
X
E
LBOW
(90
O
)
2
X
W
ALL
S
EALS
(I
NTERNAL
& E
XTERNAL
)
1
X
F
LUE
P
IPE INCLUDING
T
ERMINAL
(1
METRE
- 60/100)
1
X
F
LUE
C
LAMP
1
X
S
CREWS
1x Seal
Once the boiler has been positioned on the wall, insert the
elbow into the socket and rotate to the required position.
NOTE
:
It is possible to rotate the elbow 360
o
on its vertical axis.
Using the flue clamp, seals and screws supplied
(Fig 2.12)
secure the elbow to the boiler.
The 1 metre horizontal flue kit (3318073) supplied is suitable
for an exact
X dimension
of 815mm.
Measure the distance from the face of the external wall to the
face of the flue elbow
(X - Fig 2.9),
this figure must now be
subtracted from 815mm, you now have the total amount to be
cut from the plain end of the flue.
Draw a circle around the outer flue and cut the flue to the
required length taking care not to cut the inner flue, next cut
the inner flue ensuring that the length between the inner and
outer flue is maintained.
(Fig 2.12)
.
e.g.
X = 555mm
815-555 = 260mm (Length to be cut from the plain end of
the flue).
Once cut to the required length, ensure that the flue is free
from burrs and reassemble the flue. If fitting the flue from
inside of the building attach the grey outer wall seal to the flue
terminal and push the flue through the hole, once the wall
seal has passed through the hole, pull the flue back until the
seal is flush with the wall. Alternatively, the flue can be
installed from outside of the building, the grey outer seal
being fitted last.
Содержание ACO 27 MFFI
Страница 49: ...49 WIRING DIAGRAM FOR CONNECTION TO AN ARISTON UNVENTED CYLINDER DIAGRAM A ...
Страница 50: ...50 WIRING DIAGRAM FOR CONNECTION TO AN OPEN VENTED CYLINDER DIAGRAM B ...
Страница 57: ...57 FIG 7 19 FIG 7 20 FIG 7 21 FIG 7 22 FIG 7 23 FIG 7 24 O P FIG 7 18 ...
Страница 69: ...69 Model 27 32 RFFI SYSTEM ...
Страница 70: ...70 ...
Страница 71: ...71 ...
Страница 77: ...77 ...
Страница 78: ...78 11 BENCHMARK COMMISSIONING CHECKLIST ...
Страница 79: ...79 12 SERVICE INTERVAL RECORD ...