Legend:
A
-
ON/OFF button
B
-
Green LED (Indicates burner on)
C
-
COMFORT button
D
-
Programming key +
E
-
Central Heating temperature adjustment
F
-
Menu button
H
-
Programming key -
I
-
Domestic Hot Water temperature adjustment (MFFI only)
K
-
Comfort function LED (yellow) (MFFI only)
L
-
Red LED (indicates lockout)
M
-
Multifunction display
N
-
Reset button
O
-
EEPROM key
P
-
Interface PCB (optional)
FS
- Domestic hot water flow switch
NTC1
- Central Heating flow temperature probe
NTC2
- Central Heating return temperature probe
NTC3
- Domestic Hot Water temperature probe
(mod. 27/32 MFFI)
- Connection for boiler thermostat
(mod. 27/32 RFFI SYSTEM)
OP
- Time clock
VG
- Gas valve
M
- Diverter valve (mod. 27/32 MFFI)
CI
- Circulation pump with automatic air release valve
MV
- Fan
AC
-
Spark generator
PA
-
Air pressure switch
TA
-
Room Thermostat (optional)
TS
-
Underfloor Heating Safety Thermostat (optional)
CR*
-
Remote Control (optional)
SE*
-
External sensor (optional)
* N
OT SHOWN
CN1 =
FAN
1:
Start of coil (black)
2:
End of coil (brown)
3:
“Hall” sensor power supply 12V (red)
4:
“Hall” sensor input (white)
5:
“Hall” sensor neutral (blue)
6:
Not used
CN2 = FLAME SENSOR
CN3 = Earth
CN4 =
POWER SUPPLY
1:
Live (brown)
2:
Neutral (blue)
CN5 =
EQUIPMENT
CONNECTIONS
1:
Gas valve neutral (blue)
2:
Gas valve live (brown)
3:
Not used
4:
Pump
(V1) live (red)
5:
Pump
(V2) live (black)
6:
Pump
(ON/OFF) live (
brown
)
7:
Pump
neutral
(blue)
8:
3-way valve (C.H.) (red/black)
9:
3-way valve (D.H.W.)
(brown)
10:
3-way valve
Neutral (blue)
11: Spark generator Neutral (black)
12: Spark generator live (black)
CN6 = INTERFACE PCB
(OPTIONAL - see Section 2.12)
Accessories:
External sensor
Remote Control CLIMA MANAGER
Secondary outlet
(
see Section. 2.12
)
CN7 = DISPLAY
1: Power 5V
2: Display return
3: Display transmission
4: Earth
CN8 = SENSOR CONNECTOR
1: Central Heating flow sensor (white)
2: Central Heating return sensor (white)
3: Not used
4: DHW flow switch (grey)
5: DHW sensor (grey)
6: Air pressure switch (grey)
7: Not used
8: DHW flow switch earth (grey)
9: DHW sensor earth (grey)
10: C.H. flow sensor earth (white)
11: C.H. return sensor earth (white)
12: Air pressure switch (grey)
CN9 = ROOM THERMOSTAT
(OPTIONAL - see Section 2.12)
CN10 = UNDERFLOOR HEATING
SAFETY THERMOSTAT
(OPTIONAL - Section 2.12)
CN11 = TIME CLOCK
(see Section 2.12)
Содержание ACO 27 MFFI
Страница 49: ...49 WIRING DIAGRAM FOR CONNECTION TO AN ARISTON UNVENTED CYLINDER DIAGRAM A ...
Страница 50: ...50 WIRING DIAGRAM FOR CONNECTION TO AN OPEN VENTED CYLINDER DIAGRAM B ...
Страница 57: ...57 FIG 7 19 FIG 7 20 FIG 7 21 FIG 7 22 FIG 7 23 FIG 7 24 O P FIG 7 18 ...
Страница 69: ...69 Model 27 32 RFFI SYSTEM ...
Страница 70: ...70 ...
Страница 71: ...71 ...
Страница 77: ...77 ...
Страница 78: ...78 11 BENCHMARK COMMISSIONING CHECKLIST ...
Страница 79: ...79 12 SERVICE INTERVAL RECORD ...