Fault
TOOL ERROR HIGH
POSITION PRESS
ESC TO CONTINUE
OTHER TOOL ERRORS
PRESS ESC
TO CONTINUE
TOOL ERROR ON
TURNING PRESS
ESC TO CONTINUE
TOOL ERROR LOW
POSITION PRESS
ESC TO CONTINUE
Drive fault
EMERGENCY-STOP
FAULT X-AXIS / AIR
PRESSURE
X-AXIS SERVO-AMPLIFIER
NOT READY
ERROR X-AXIS INTEGRAL
PRESS ESC-KEY
ERROR Y-AXIS INTEGRAL
PRESS ESC-KEY
ERROR X-AXIS DIFF.
PRESS ESC-KEY
ERROR Y-AXIS DIFF.
PRESS ESC-KEY
ERROR IO-BOARD
SWITCH ON PLOTTER
AGAIN
ERROR Y-BOARD SWITCH
ON PLOTTER AGAIN
Cause
1.The axis are blocked
2.Defective machine control
3.The material is too thick
1.The motor’s temperature is
too high
2.There is not enough com-
pressed air
1.The amplifier is either
overloaded or defective
1.Blocking of the axis due to
material
2.Defective machine control
3.Feeding speed and/or
acceleration is too high
1.Defective machine control
Remedy
1.Switch off drives and
check tool. Press ESC and
switch on drives to continue
2.Choose menu SETTINGS,
MATERIAL Thickness
3.Mount the tool head in a
higher position
1.Switch off the ARISTOMAT
and cool down the motor
2.Increase compressed air
setting at maintenance unit
or compressor
1.Switch the ARISTOMAT off
and on
1.Remove the blocking
material from the axis. Press
ESC and switch on drives
again
2.Call a service technician
3.Reduce parameters FEED
and ACCELERATION
1.Call a service technician
Содержание ARISTOMAT CL 1310
Страница 1: ...ARISTOMAT CL 131O 1317 1617 Users Manual ...
Страница 6: ......
Страница 21: ...ARISTOMAT CL 23 System Start Up Vacuum zones ARISTOMAT 131O ...
Страница 22: ...24 ARISTOMAT CL System Start Up ARISTOMAT 1317 ...
Страница 23: ...ARISTOMAT CL 25 System Start Up ARISTOMAT 1617 ...
Страница 24: ...26 ARISTOMAT CL System Start Up ...
Страница 30: ...32 ARISTOMAT CL Menu Tables ...
Страница 50: ...52 ARISTOMAT CL Specifications ...
Страница 54: ...56 ARISTOMAT CL Technical Hints ...
Страница 55: ...ARISTOMAT CL 57 ...