Technical Hints
Fault
HPGL Fault
IGNORED INSTRUCTION
UNRECOGN. HPGL-IN-
STRUC.
User fault
TOOL CHANGE
RECOGNISED SWITCH ON
PLOTTER AGAIN
MOVE BRIDGE AWAY
FROM LIMIT AGAIN
MOVE TOOL CARRIAGE
AWAY FROM LIMIT
SWITCH
UNLOCK EMERGENCY-
OFF BUTTON
Tool Fault
FAULT C-AXIS PRESS
ENTER TO CONTINUE
FAULT Z-AXIS PRESS
ENTER TO CONTINUE
Cause
1.Sent data from the compu-
ter contain HPGL instruction,
which the ARISTOMAT does
not understand
1.The ARISTOMAT was not
switched off when changing
tools
1.The main power switch
was turned off before switch-
ing off the drives
2.The bridge or the tool
carriage were moved to the
limit switch
1.EMERGENCY OFF button
was locked
2.Defective machine control
1.Defective or jammed tool
head
Remedy
1.These messages are just
for your information. Only the
last unknown HPGL com-
mands is shown
1.Restart the ARISTOMAT
1.Remove the bridge or the
tool carriage manually from
the limit switch and switch on
the drives
1.Unlock EMERGENCY
button
2.Call a service technician
1.Call a service technician
11. Technical Hints
Note:
If faults occur several times, the operating sequence and the fault message should
be written down and the ARISTO service should be informed.
Содержание ARISTOMAT CL 1310
Страница 1: ...ARISTOMAT CL 131O 1317 1617 Users Manual ...
Страница 6: ......
Страница 21: ...ARISTOMAT CL 23 System Start Up Vacuum zones ARISTOMAT 131O ...
Страница 22: ...24 ARISTOMAT CL System Start Up ARISTOMAT 1317 ...
Страница 23: ...ARISTOMAT CL 25 System Start Up ARISTOMAT 1617 ...
Страница 24: ...26 ARISTOMAT CL System Start Up ...
Страница 30: ...32 ARISTOMAT CL Menu Tables ...
Страница 50: ...52 ARISTOMAT CL Specifications ...
Страница 54: ...56 ARISTOMAT CL Technical Hints ...
Страница 55: ...ARISTOMAT CL 57 ...