1: if no sensor is connected
1
0/1
Low contrast
0: if measurement contrast is high
1: if measurement contrast is low
2
0/1
No web
0: if web is detected by the sensor
1: if the sensor cannot detect a web
3
0/1
Wrong
orientation
0: if sensor orientation is correct
1: if the sensor see an edge in the opposite orientation to which it is set up
4
NA
Reserved for future use
5
0/1
Flutter
0: if no flutter is detected
1: if the sensor detects flutter or out of plane movement in the web
6
NA
Reserved for future use
7
0/1
WPS or ODC
0: WPS Sensor
1: ODC
8
0/1
Left Sensor
0: if the sensor not set as a left sensor
1: if the sensor is set as a left sensor
9
0/1
Right Sensor
0: if the sensor not set as a right sensor
1: if the sensor is set as a right sensor
10-13
1-15
Number of
pixels
The number of pixels in the sensor and the corresponding sensor resolution.
When bit 7 is zero:
0: 256 WPS 16 (0.0635 mm)
1: 768 WPS 48 (0.0635 mm)
2: 1774 WPS 221 (0.125 mm)
3: 896 WPS 112 (0.127 mm)
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 48
Copyright © 2021 Roll-2-Roll Technologies LLC
+1-888-290-3215