Output
0x1D00
16
8-bit
Controller Output and PLC Input
#
bit
15
bit
14
bit
13
bit
12
bit
11
bit
10
bit
9
bit
8
bit
7
bit
6
bit
5
bit
4
bit
3
bit
2
bit
1
bit
0
0
Sensor 1 Fault and Status Codes
1
Sensor 2 Fault and Status Codes
2
Sensor 1: Left Edge
3
Sensor 1: Right Edge or Contrast Position
4
Sensor 1: Coverage
5
Sensor 2: Left Edge
6
Sensor 2: Right Edge or Contrast Position
7
Sensor 2: Coverage
8
Sensor 1 QF
Sensor 2 QF
9
Web guide status/fault register
10
Guide point offset
11
Motor Speed Percentage
Motor Acceleration Percentage
12
Sensor 1: Thread Count
13
Sensor 2: Thread Count
14
Sensor 1: Mean Width or Total Web Width
15
Sensor 2: Mean Width or Total Web Width
Sensor status and fault registers
The sensor status/fault register is organized as follows. The eight least significant bits correspond to fault
information while the eight most significant bits correspond to status information.
Bit #
Value
Label
Description
0
0/1
No sensor
0: if a sensor is present
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 47
Copyright © 2021 Roll-2-Roll Technologies LLC
+1-888-290-3215