MAC address
The MAC address of the ethernet module on the SCU5 controller is displayed here. This value cannot be
changed.
Module Type
The type of the industrial ethernet module in the SCU5 controller will be printed over the network LED. The
available fieldbus options are EtherNet/IP, PROFINET, EtherCAT and Modbus/TCP. If no module is available
on the SCU5 controller then the module type would be None.
Network IC Type
Some versions of the SCU5 controller also identify the type of network IC installed. The two options are HMS
and Hilscher. If the correct network IC is not initialized then it will appear as none.
NOTE:
If all of the address fields and the mac address is zero, then the ethernet module is not initialized.
Make sure to turn ON ethernet and power cycle the controller. If the problem persists, you may not have an
ethernet module on your controller or the ethernet module on the controller is faulty. Please consult the
factory for more information.
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 45
Copyright © 2021 Roll-2-Roll Technologies LLC