Analog Output (Port 2)
The SCU5 controller without the motor suffix will include a 3-pin Male M8 connector for analog output. The
pinouts for the connector are shown below.
Pin
Color
Signal
1
Brown
Voltage
3
Blue
Current
4
Black
Ground/Common
The outputs can be chosen via the touchscreen interface to any of the following available output options:
Voltage
Current
0 - 5 V, 0 - 10 V, ± 5 V, ± 10 V
4 - 20 mA, 0 - 20 mA, 0 - 24 mA
WARNING:
These pins are isolated outputs. Do not connect a power source to these pins. Some analog
input cards on PLC might have a voltage source to power sensors. Please do not connect the voltage source
to these pins. This might permanently damage the controller.
Industrial Ethernet Interface (Port 3)
An optional industrial ethernet connection is available on models with suffix C(E) or C(P). A 4-pin D-coded
M12 socket connect is provided for ethernet connection. Standard network cables such as Phoenix Contact
NBC-MSD/ 1,0-93E/R4AC SCO - 1407360
or
can be used to connect the
SCU5 M to an ethernet network using RJ45 plug.
Pin
Color
Signal
1
White/Orange
+TX
2
White/Green
+RX
3
Orange
-TX
4
Green
-RX
Content subject to change without notice
SCU5: Sensor and Web Guide Controller User Manual v 3.6| Page 12