This instruction manual covers the installation, operation and troubleshooting of the Argus RST se-
ries of switched mode rectifier/battery eliminator.
3.2
Introduction
The RST series of rectifiers employs a high frequency switched mode conversion technique that
provides a fully regulated and isolated DC output from the AC mains. The 48 volt rectifiers are in-
tended to be used in a positive ground configuration, however 24 volt units can be ordered in either
positive or negative ground configuration. The units are fully functional battery eliminators and
therefore do not require an external battery to meet the performance requirements as outlined in the
specification section of this manual.
3.3
Features
3.3.01 . . . . . . . Digital Voltmeter/Ammeter
3.3.02 . . . . . . . Indicators
3.3.03 . . . . . . . Power On Indicator
3.3.04 . . . . . . . Float Mode
3.3.05 . . . . . . . Equalize Mode
3.3.06 . . . . . . . Test Mode
3.3.07 . . . . . . . Alarms - General
3.3.08 . . . . . . . Rectifier Fail Alarm
3.3.09 . . . . . . . Low Voltage Alarm
3.3.10 . . . . . . . Current Limit
3.3.11 . . . . . . . Over Voltage Shutdown
3.3.12 . . . . . . . Remote Equalize
3.3.13 . . . . . . . Remote Shutdown
3.3.14 . . . . . . . Remote Restart
3.3.15 . . . . . . . Start Delay
3.3.16 . . . . . . . Soft Start
3.3.17 . . . . . . . Output Slope
3.3.18 . . . . . . . Input/Output Circuit Breakers
3.3.19 . . . . . . . AC Hi/Lo voltage Shutdown
3.3.20 . . . . . . . Front to Back Ventilation
3.3.21 . . . . . . . Over Temperature Protection
3.3.22 . . . . . . . Battery Eliminator Operation
3.3.23 . . . . . . . Remote Sense
3.3.01
Digital Voltmeter/Ammeter
Located on the front panel of the unit is a 3 digit (3 1/2 for 100 amp units) LED display. Normally,
the display indicates the output current of the rectifier. The display is updated every third of a sec-
ond to eliminate annoying display jitter yet provides a fast response for rapidly changing output con-
ditions. Located underneath the display is a push button labelled “Depress to display Volts”. When
this button is held down the display will indicate the output voltage of the unit. Output current read-
ings are accurate to within 2% while voltage measurements are accurate to within 0.2%. Sensing
for the meter is before the output breaker of the unit. Therefore only the true output of the rectifier is
displayed.