163
WEB BROWSER-BASED CONFIGURATION
6.11.1.2 For ARC-5030
• System Beeper Setting
The Alert Beeper function item is used to Disabled or Enable the
RAID subsystem controller alarm tone generator.
• Background Track Priority
The Raid background Track Priority is a relative indication of
how much time the controller devotes to a background opera-
tion such as rebuilding or migrating. The RAID subsystem allows
user to choose the background priority to balance volume set
access and background tasks appropriately. For high array per-
formance, specify a Low value.
• Terminal Port Configuration
Speed setting values are 1200, 2400, 4800, 9600, 19200,
38400, 57600, and 115200.
Stop Bits values are 1 bit and 2 bits.
Note: Parity value is fixed at None.
Data Bits value is fixed at 8 bits.
• JBOD/RAID Configuration
JBOD is an acronym for “Just a Bunch Of Disk”. It repressents a
volume set that is created by the concatenation of partitions on
the disks. For the ARC-5030, it can only see the first two disks,
when you select the JBOD option. User needs to delete the RAID
set, when you want to change the option from the RAID to the
JBOD function.
• Max SATA Mode Supported
Within the subsystem, the host IDE channels act as a target
and 5 Serial ATA ll bus are connected to the drive. The 5 SATA
ll drive channel can support up to SATA ll, which runs up to
Содержание ARC-5030 Series