WEB BROWSER-BASED CONFIGURATION
142
3
Select a Drive For Raid Set window is displayed showing the IDE drive
connected to the current controller.
4
Press
UP
and
DOWN
arrow keys to select specific physical drives. Press
the
Enter
key to associate the selected physical drive with the current
raid set.
Recommend use drives has same capacity in a specific raid set. If you
use drives with different capacities in an array, all drives in the raid set
will select the lowest capacity of the drive in the raid set.
The numbers of physical drives in a specific raid set determine the RAID
levels that can be implemented with the raid set.
RAID 0 requires 1 or more physical drives.
RAID 1 requires at least 2 physical drives.
RAID 1+Spare requires at least 3 physical drives.
RAID 3 requires at least 3 physical drives.
RAID 5 requires at least 3 physical drives.
RAID 6 requires at least 4 physical drives.
RAID 3 + Spare requires at least 4 physical drives.
RAID 5 + Spare requires at least 4 physical drives.
RAID 6 + Spare requires at least 5 physical drives.
5
After adding physical drives to the current raid set as desired, press Yes
to confirm the Create Raid Set function.
6
An Edit The Raid Set Name dialog box appears. Enter 1 to 15 alphanu-
meric characters to define a unique identifier for a raid set. The default
raid set name will always appear as Raid Set. #. Press Enter to finish the
name editing.
7
Press
Enter
key when you are finished creating the current raid set. To
continue defining another raid set, repeat step 3. To begin volume set
configuration, go to step 8.
8
Choose
Volume Set Function
from the Main menu. Select the
Create
Volume Set
and press
Enter
key.
9
Choose one raid set from the Create Volume From Raid Set window. Press
Enter key to confirm it.
10
The Volume Creation screen shows the volume set default attribute val-
ues that are currently being configured. The attribute column headings
are:
The Raid Level,
The Stripe Size,
The SCSI HOST/SCSI ID/SCSI LUN (ARC-6020)
The IDE Host channel /IDE Driver select (ARC-5030)
The Cache Mode,
The Tagged Queuing,
The SCSI Max Rate (ARC-6020),
The IDE Xfer Mode (ARC-5030) and
The Volume Name (number).
The user can change all values
After the current volume set attributes are defined, press Esc key to en
-
ter Initialization selection screen.
Содержание ARC-5030 Series
Страница 11: ......
Страница 74: ...LCD CONFIGURATION MENU 74 Figure 4 8 4 2 ARC 6020...