PRODUCT DESCRIPTION

ORION X is a flowmeter, namely a device allowing to measure the quantity of liquid flowing through it. ORION X is an electromagnetic device, hence 
there are no moving parts. The VISUALFLOW version, in addition, allows displaying the flowrate and dispensed volume as well as managing the 
filling of a tank

1.1 

Intended use

This device is designed to work on agricultural machinery for spraying and crop spraying applications.

The equipment is designed and built in compliance with EN ISO 14982 standard (Electromagnetic compatibility - Forestry and 

farming machines), harmonized with 2014/30/EU Directive.

THE FLOWMETER MUST NOT BE USED TO MEASURE THE PASSAGE OF HYDROCARBONS, FLAMMABLE, EXPLOSIVE OR 

TOXIC LIQUIDS. THE FLOWMETER IS NOT SUITABLE FOR CONTACT WITH LIQUIDS FOR HUMAN CONSUMPTION. USE FOR 
SALES TRANSACTIONS IS NOT ALLOWED.

INSTALLATION

FREQ

CAN

FREQ

CAN

VISUALFLOW

Respect liquid flow 
direction, as indicated 
by the arrow.

ORION X must be connected 
with two T9 fork fittings and 
relevant O-rings.

The connecting cables 
must be ordered 
separately (refer 
to ARAG General 
Catalog).

ORION X features two 
connecting ports, with 
frequency or CanBus (A-net) 
outputs.

CONTINUES

MAX

5 bar (72 PSI)

Connectors must be inserted 
with special care in order not to 
damage the seal and by pressing 
them until hearing a click of the 
retaining tooth.

ORION X features 4 seats 
to fasten the M8 hex.head 
screws.

To remove the connector, lift the tab and take 
out the connector body.

Содержание orionX

Страница 1: ...4629XXXX ELECTROMAGNETIC FLOWMETER INSTALLATION USE AND MAINTENANCE VISUALFLOW...

Страница 2: ...otalizer reset 9 6 6 Use for tank filling function 10 7 MAINTENANCE 11 8 ERRORS TROUBLESHOOTING 11 9 TECHNICAL DATA 12 9 1 Dimensions 12 9 2 Performance 12 9 3 Display 12 9 4 Electrical features 12 9...

Страница 3: ...NOT BE USED TO MEASURE THE PASSAGE OF HYDROCARBONS FLAMMABLE EXPLOSIVE OR TOXIC LIQUIDS THE FLOWMETER IS NOT SUITABLE FOR CONTACT WITH LIQUIDS FOR HUMAN CONSUMPTION USE FOR SALES TRANSACTIONS IS NOT...

Страница 4: ...length is at least 10 times the inner diameter of OrionX 75mm x 10 750 mm Install the flowmeter far from the elements that could cause turbulence inside the pipe valves bends bottlenecks etc It is re...

Страница 5: ...fittings and on pipes For the connections use pipes and fittings duly dimensioned for system operating pressure MAX 5 bar Hose tails must be tightened with special metal clips ensuring a perfect seali...

Страница 6: ...reading electrodes in progress RED BLINKING RED Error The error codes are indicated through blinks which are described in the table below RED STEADY ON SEVERE ERROR contact a service center Signals th...

Страница 7: ...so generates the pump stop signal Menu Description Operator Manager Technician 1 Sensor Settings Min flowrate Threshold Minimum flowrate under which the output signal will no longer be generated The v...

Страница 8: ...nsor name Name of the sensor display only l l l 23 Diagnostics Sensor properties Serial number Sensor serial number display only l l l 24 Diagnostics Sensor properties Hardware version Sensor Hardware...

Страница 9: ...izer reset To reset a totalizer you must view it in extended mode Press key several times until value to be reset is at the central area of the display Press the key for two seconds Totalizer resets S...

Страница 10: ...ave changes or D Press to quit the page without confirming changes 3 Keep key pressed for two seconds Filling starts The display shows the following data top part set filling quantity central part par...

Страница 11: ...supply voltage too high or too low Check the power supply voltage and restore the correct value Unstable reading 5 Unstable reading Check that the flow is normal and make sure to have complied with th...

Страница 12: ...m3 h Filling mode Yes Volume counter mode Yes Partial totalizers 2 9 4 ELECTRICAL FEATURES Power supply voltage 9 16 Vdc Maximum absorption 300 mA Protection against polarity inversion Yes Protection...

Страница 13: ...t 906 1670 g according to the type Flange T9 Coupling Clamp Coupling 3 Full Port 9 7 MATERIALS Electrodes Stainless steel Aisi 316 Rings Stainless steel Aisi 316 Body fiber glass reinforced PA 6 Pipe...

Страница 14: ...lters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance...

Страница 15: ...Notes 15...

Страница 16: ...ilia ITALY Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained...

Отзывы: