background image

14

10 

GUARANTEE TERMS

 

1.  ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery note).
 

The components of the apparatus, that in the unappealable opinion of ARAG are faulty due to an original defect in the material or production pro-
cess, will be repaired or replaced free of charge at the nearest Assistance Center operating at the moment the request for intervention is made. 

 

The following costs are excluded:

disassembly and reassembly of the apparatus from the original system;

transport of the apparatus to the Assistance Center.

2.  The following are not covered by the guarantee:

damage caused by transport (scratches, dents and similar);

damage due to incorrect installation or to faults originating from insufficient or inadequate characteristics of the electrical system, or to alterations 
resulting from environmental, climatic or other conditions;

damage due to the use of unsuitable chemical products, for spraying, watering, weedkilling or any other crop treatment, that may damage the ap-
paratus;

malfunctioning caused by negligence, mishandling, lack of know how, repairs or modifications carried out by unauthorized personnel;

incorrect installation and regulation;

damage or malfunction caused by the lack of ordinary maintenance, such as cleaning of filters, nozzles, etc.;

anything that can be considered to be normal wear and tear.

3.  Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance Center.
 

No guarantee conditions will be recognized for those units or components that have not been previously washed and cleaned to remove residue of 
the products used;

4.  Repairs carried out under guarantee are guaranteed for one year (360 days) from the replacement or repair date.
5.  ARAG will not recognize any further expressed or intended guarantees, apart from those listed here.
 

No representative or retailer is authorized to take on any other responsibility relative to ARAG products.

 

The period of the guarantees recognized by law, including the commercial guarantees and allowances for special purposes are limited, in length of 
time, to the validities given here. 

 

In no case will ARAG recognize loss of profits, either direct, indirect, special or subsequent to any damage.

6.  The parts replaced under guarantee remain the property of ARAG.
7.  All safety information present in the sales documents regarding limits in use, performance and product characteristics must be transferred to the 

end user as a responsibility of the purchaser.

8.  Any controversy must be presented to the Reggio Emilia Law Court.

11 

END-OF-LIFE DISPOSAL

Dispose of the system in compliance with the established legislation in the country of use.

12 

CONFORMITY DECLARATION

The declaration of conformity is available at www.aragnet.com, in the relevant section.

Содержание orionX

Страница 1: ...4629XXXX ELECTROMAGNETIC FLOWMETER INSTALLATION USE AND MAINTENANCE VISUALFLOW...

Страница 2: ...otalizer reset 9 6 6 Use for tank filling function 10 7 MAINTENANCE 11 8 ERRORS TROUBLESHOOTING 11 9 TECHNICAL DATA 12 9 1 Dimensions 12 9 2 Performance 12 9 3 Display 12 9 4 Electrical features 12 9...

Страница 3: ...NOT BE USED TO MEASURE THE PASSAGE OF HYDROCARBONS FLAMMABLE EXPLOSIVE OR TOXIC LIQUIDS THE FLOWMETER IS NOT SUITABLE FOR CONTACT WITH LIQUIDS FOR HUMAN CONSUMPTION USE FOR SALES TRANSACTIONS IS NOT...

Страница 4: ...length is at least 10 times the inner diameter of OrionX 75mm x 10 750 mm Install the flowmeter far from the elements that could cause turbulence inside the pipe valves bends bottlenecks etc It is re...

Страница 5: ...fittings and on pipes For the connections use pipes and fittings duly dimensioned for system operating pressure MAX 5 bar Hose tails must be tightened with special metal clips ensuring a perfect seali...

Страница 6: ...reading electrodes in progress RED BLINKING RED Error The error codes are indicated through blinks which are described in the table below RED STEADY ON SEVERE ERROR contact a service center Signals th...

Страница 7: ...so generates the pump stop signal Menu Description Operator Manager Technician 1 Sensor Settings Min flowrate Threshold Minimum flowrate under which the output signal will no longer be generated The v...

Страница 8: ...nsor name Name of the sensor display only l l l 23 Diagnostics Sensor properties Serial number Sensor serial number display only l l l 24 Diagnostics Sensor properties Hardware version Sensor Hardware...

Страница 9: ...izer reset To reset a totalizer you must view it in extended mode Press key several times until value to be reset is at the central area of the display Press the key for two seconds Totalizer resets S...

Страница 10: ...ave changes or D Press to quit the page without confirming changes 3 Keep key pressed for two seconds Filling starts The display shows the following data top part set filling quantity central part par...

Страница 11: ...supply voltage too high or too low Check the power supply voltage and restore the correct value Unstable reading 5 Unstable reading Check that the flow is normal and make sure to have complied with th...

Страница 12: ...m3 h Filling mode Yes Volume counter mode Yes Partial totalizers 2 9 4 ELECTRICAL FEATURES Power supply voltage 9 16 Vdc Maximum absorption 300 mA Protection against polarity inversion Yes Protection...

Страница 13: ...t 906 1670 g according to the type Flange T9 Coupling Clamp Coupling 3 Full Port 9 7 MATERIALS Electrodes Stainless steel Aisi 316 Rings Stainless steel Aisi 316 Body fiber glass reinforced PA 6 Pipe...

Страница 14: ...lters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance...

Страница 15: ...Notes 15...

Страница 16: ...ilia ITALY Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained...