background image

10

6.6 

Use for tank filling function

top part:

 

item

 

Start

 

refers to the key on the side allowing user to start the procedure 

(key

 

 

);

central part:

 

the value is the set filling quantity (in liters). On the side, the symbol

 

o

 

 is displayed;

bottom part:

 

item

 

Quantity

 

refers to the key on the side which allows user to set

tank filling value (key

 

 

).

1) Press the key 

 for two seconds to open the menu for setting the filling quantity.

2) Set filling quantity:

A)

 

Press to move through digits

B)

 

Press a few times to edit the highlighted digit

C) Press to save changes, or D) Press to quit the page without confirming changes.

3) Keep key 

 pressed for two seconds. Filling starts.

The display shows the following data:

top part:

 set filling quantity;

central part:

 partial totalizer;

bottom part:

 instant flowrate.

Press key 

 

several times to view a value in extended mode until the required value is 

displayed in the central part.

Displayed values cannot be edited.

Tank filling can be interrupted at any time by pressing 

ESC

. Pause message will be shown 

at the bottom of the display.
Press 

OK

 to resume filling;

Press 

ESC

 to finally stop filling and display will go back to initial page.

When set quantity is reached, filling stops automatically. Completed message will be shown at 
the bottom of the display.

Содержание orionX

Страница 1: ...4629XXXX ELECTROMAGNETIC FLOWMETER INSTALLATION USE AND MAINTENANCE VISUALFLOW...

Страница 2: ...otalizer reset 9 6 6 Use for tank filling function 10 7 MAINTENANCE 11 8 ERRORS TROUBLESHOOTING 11 9 TECHNICAL DATA 12 9 1 Dimensions 12 9 2 Performance 12 9 3 Display 12 9 4 Electrical features 12 9...

Страница 3: ...NOT BE USED TO MEASURE THE PASSAGE OF HYDROCARBONS FLAMMABLE EXPLOSIVE OR TOXIC LIQUIDS THE FLOWMETER IS NOT SUITABLE FOR CONTACT WITH LIQUIDS FOR HUMAN CONSUMPTION USE FOR SALES TRANSACTIONS IS NOT...

Страница 4: ...length is at least 10 times the inner diameter of OrionX 75mm x 10 750 mm Install the flowmeter far from the elements that could cause turbulence inside the pipe valves bends bottlenecks etc It is re...

Страница 5: ...fittings and on pipes For the connections use pipes and fittings duly dimensioned for system operating pressure MAX 5 bar Hose tails must be tightened with special metal clips ensuring a perfect seali...

Страница 6: ...reading electrodes in progress RED BLINKING RED Error The error codes are indicated through blinks which are described in the table below RED STEADY ON SEVERE ERROR contact a service center Signals th...

Страница 7: ...so generates the pump stop signal Menu Description Operator Manager Technician 1 Sensor Settings Min flowrate Threshold Minimum flowrate under which the output signal will no longer be generated The v...

Страница 8: ...nsor name Name of the sensor display only l l l 23 Diagnostics Sensor properties Serial number Sensor serial number display only l l l 24 Diagnostics Sensor properties Hardware version Sensor Hardware...

Страница 9: ...izer reset To reset a totalizer you must view it in extended mode Press key several times until value to be reset is at the central area of the display Press the key for two seconds Totalizer resets S...

Страница 10: ...ave changes or D Press to quit the page without confirming changes 3 Keep key pressed for two seconds Filling starts The display shows the following data top part set filling quantity central part par...

Страница 11: ...supply voltage too high or too low Check the power supply voltage and restore the correct value Unstable reading 5 Unstable reading Check that the flow is normal and make sure to have complied with th...

Страница 12: ...m3 h Filling mode Yes Volume counter mode Yes Partial totalizers 2 9 4 ELECTRICAL FEATURES Power supply voltage 9 16 Vdc Maximum absorption 300 mA Protection against polarity inversion Yes Protection...

Страница 13: ...t 906 1670 g according to the type Flange T9 Coupling Clamp Coupling 3 Full Port 9 7 MATERIALS Electrodes Stainless steel Aisi 316 Rings Stainless steel Aisi 316 Body fiber glass reinforced PA 6 Pipe...

Страница 14: ...lters nozzles etc anything that can be considered to be normal wear and tear 3 Repairing the apparatus will be carried out within time limits compatible with the organizational needs of the Assistance...

Страница 15: ...Notes 15...

Страница 16: ...ilia ITALY Tel 39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained...

Отзывы: