10
6.6
Use for tank filling function
-
top part:
item
Start
refers to the key on the side allowing user to start the procedure
(key
);
-
central part:
the value is the set filling quantity (in liters). On the side, the symbol
o
is displayed;
-
bottom part:
item
Quantity
refers to the key on the side which allows user to set
tank filling value (key
).
1) Press the key
for two seconds to open the menu for setting the filling quantity.
2) Set filling quantity:
A)
Press to move through digits
B)
Press a few times to edit the highlighted digit
C) Press to save changes, or D) Press to quit the page without confirming changes.
3) Keep key
pressed for two seconds. Filling starts.
The display shows the following data:
-
top part:
set filling quantity;
-
central part:
partial totalizer;
-
bottom part:
instant flowrate.
Press key
several times to view a value in extended mode until the required value is
displayed in the central part.
Displayed values cannot be edited.
Tank filling can be interrupted at any time by pressing
ESC
. Pause message will be shown
at the bottom of the display.
Press
OK
to resume filling;
Press
ESC
to finally stop filling and display will go back to initial page.
When set quantity is reached, filling stops automatically. Completed message will be shown at
the bottom of the display.