7
6.3
STRUCTURE OF THE SETTING MENU (
ORION X VISUALFLOW)
(1): Item available only if the “Volume Counter” operating mode has been selected.
(2): Item available only if the “Filling Check” operating mode has been selected.
KEY
- sensor: the part of the flowmeter carrying out the liquid reading and generating the output in frequency and CANBUS (it is present both
in ORION X and ORION X VISUALFLOW versions)
- display: available only in the ORION X VISUALFLOW version, it communicates with sensor electronics and allows displaying / editing
the flowmeter parameters. The display also generates the pump stop signal.
#
Menu
Description
Oper
at
or
Mana
g
er
Tec
hnician
1
Sensor > Settings > Min. flowrate Threshold
Minimum flowrate under which the output signal will no longer be generated.
The value is expressed in % of the full scale (Example: full scale 2500 l/min,
min. flowrate threshold 2.5% = 62.5).
This parameter proves useful to avoid false readings with still liquid and thus the
generation of a wrong output signal.
If the flowrate falls below the set value:
- the frequency output is set to 0
- the CAN data indicate a flowrate equal to 0
- the Display shows a flowrate equal to 0
l
2
Sensor > Totalizers > Total volume
It displays the liquid total volume measured by the sensor
l
l
l
3
Sensor > Totalizers > Lifetime
It displays sensor total operating time
l
l
l