background image

3

www.aquascapeinc.com | 

☎ 

CAN 1-866-766-3426 | 

☎ 

US 1-866-877-6637

Exploded View

Ultra

 1100/1500/2000

Introduction

Aquascape Ultra

 Pumps are the complete solution for 

small ponds, fountains and water features. This all-in-
one kit includes a three-way diverter valve and multi-size 
connection, making it adaptable to almost any hose or 
tubing size. Ultra pumps are ideal for supplying water to 

run fountains, water features, external filters and spitting 
ornaments. This combination of energy-efficient mag-drive 
performance, flow, and ease of maintenance make this 
pump the ideal choice for discriminating pond owners.

Contents

(1) Ultra

 Pump

Replacement Parts

Contact your local dealer for replacement parts required due to damage or wear.

Optional Accessories

Ultra Pump

 Fountain Head Kits

If you currently own an Ultra Pump

 and want to add a new dimension 

to your pond with the addition of a fountain, Aquascape makes it simple 

with the addition of the new Ultra Pump

 Fountain Head Kit. Kit comes 

complete with three fountain heads: Water Bell, Foaming Jet, and Daisy 

Fountain along with an integrated diverter valve to adjust the fountain 

head height, as well as allows for the diversion of water to an external 

filter or waterfall.

1

 Front Cover

2

 Filter Sponge

3

 Water Chamber Assembly

4

 Impeller Assembly

5

 Rubber Feet

6

 Main Housing

7

 Back Cover

8

 ¾”, 1”, 1½” Multi Hose Adapter

9

  ½” Barb Valve

1

 Front Cover

2

 Filter Sponge

3

 Water Chamber Assembly

5

 Impeller Assembly

5

 Rubber Feet

6

 Main Housing

7

 Back Cover

8

  ¾” x ¾”, 1”, 1¼”  

Multi Hose Adapter

9

  ¾” 3-way Valve

10

  ¾” x 1”, 1¼”, 1½” Multi Hose 

Adaptor (1500 & 2000)

Parts List

 

For Models 400/550/800 only

Parts List

 

For Models 1100/1500/2000 only

#91055 Ultra

 Pump  

Discharge Fittings Kit  

For Models 400/550/800

(1) ½” x ½” Barb Valve
(1)  ½” Multi Hose Adapter  

x ¾”, 1”, 1¼”

½” Valve

(Ultra

 400, 

550, 800)

1”, 1¼”, 1½”

Multi Hose Adapter

(Ultra

 1500, 2000)

¾”, 1”, 1¼”

Multi Hose 

Adapter

¾” 3 -Way Valve

(Ultra

 1100, 

1500, 2000)

Pump 

Model

Front  

Cover Kit

Filter 

Sponge

Impeller Kit

Discharge  

Fittings Kit

400

91050

91033 (4/pkg)

91039

91055

550

91051

91034 (4/pkg)

91040

91055

800

91051

91035 (4/pkg)

91041

91055

1100

91052

91036 (2/pkg)

91042

91057

1500

91053

91037 (2/pkg)

91043

91057

2000

91053

91038 (2/pkg)

91044

91057

Ultra

 Pump Fountain Head Kit Specs

Model #

Kit Item #

Waterbell 

Fountain

Spray Diameter

Foaming Jet

Spray Height

Daisy Fountain

Spray Height

Ultra

 400

91045

up to 12” 

up to 12”

up to 40”

Ultra

 550

91045

up to 15”

up to 16”

up to 47”

Ultra

 800

91045

up to 21”

up to 18”

up to 52”

Ultra

 1100

91046

up to 31”

up to 20”

up to 76”

Ultra

 1500

91046

up to 34”

up to 22”

up to 86”

Ultra

 2000

91046

up to 36”

up to 24”

up to 96”

Waterbell

Foaming Jet

Daisy

Fountain Head Kit

#91057 Ultra

 Pump  

Discharge Fittings Kit  

For Models 1100/1500/2000

(1)  ¾” Multi Hose Adapter  

x ¾”, 1”, 1¼” 

(1)  ¾” 3-Way Valve x ¾”  

Barbed Discharge

(1) ¾" Multi Hose Adapter  

x 1”, 1¼”, 1½” (1500 & 2000)

4

3

1

2

1

7

5

9

8

2

3

4

6

2

3

4

1

1

9

7

8

10

2

3

5

4

6

Exploded View

Ultra

 400/550/800

91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd   3

10/3/14   3:12 PM

Содержание Signature series 400

Страница 1: ...mp For Models 400 Item 91005 550 Item 91006 800 Item 91007 1100 Item 91008 1500 Item 91009 2000 Item 91010 Available in flow rates from 400 to 2000 GPH I N S T R U C T I O N S M A I N T E N A N C E Ul...

Страница 2: ...efective No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is assumed by Aquascape Inc or its affiliates Co...

Страница 3: ...r 8 1 1 Multi Hose Adapter 9 Barb Valve 1 Front Cover 2 Filter Sponge 3 Water Chamber Assembly 5 Impeller Assembly 5 Rubber Feet 6 Main Housing 7 Back Cover 8 x 1 1 Multi Hose Adapter 9 3 way Valve 10...

Страница 4: ...o lift pump Installation Always operate the pump fully submerged Failure to do so will overheat the pump and cause it to fail thus voiding the warranty DO NOT OPERATE DRY Use only in fully assembled s...

Страница 5: ...ative fountain container To maximize pond circulation locate the pump as far away as possible from the location of the water entering back into the water feature Pond with external filter Decorative F...

Страница 6: ...tected by a ground fault interrupter Once the pump is running and water is circulating through the filter s or waterfalls check for any fitting or waterfall leaks where the external connections are ma...

Страница 7: ...ler Kits are available through your local Aquascape dealer 1a Note the orientation of parts in the photo below The replacement impeller kits include all parts shown Make sure to remove all of the orig...

Страница 8: ...rotor assembly and internal pump body Make sure nothing is blocking or wrapped around the impeller Make sure the pump is receiving the correct voltage Pump Not Working The ground fault circuit interru...

Страница 9: ...no 91005 550 article no 91006 800 article no 91007 1100 article no 91008 1500 article no 91009 2000 article no 91010 Disponible en d bits de 1514 7570 L h Ultra MC 400 550 800 1100 Ultra MC 1500 2000...

Страница 10: ...uts dans les mat riaux et les d fauts de fabrication seulement Le remplacement de l unit d fectueuse par une unit de rechange appropri e sera la seule obligation Les unit s devront tre v rifi es afin...

Страница 11: ...usqu 86 36 cm Jusqu 55 88 cm Jusqu 218 44 cm UltraMC 2000 91046 Jusqu 91 44 cm Jusqu 60 96 cm Jusqu 243 84 cm Cloche d eau Jet moussant Fontaine marguerite Trousse de t tes de fontaines Mod le de pomp...

Страница 12: ...son utilisation sinon elle pourrait surchauffer entra nant ainsi sa d faillance et annulant de ce fait la garantie NE FAITES PAS FONCTIONNER LA POMPE SEC Utilisez seulement lorsque la pompe est enti r...

Страница 13: ...lan d eau ou une fontaine d corative La pompe UltraMC est con ue pour tre submerg e directement dans le plan d eau ou le r servoir de la fontaine d corative Pour maximiser la circulation d eau dans le...

Страница 14: ...filtration de la pompe Dans de nombreux cas la cage de filtration bouch e peut tre nettoy e en plongeant la main dans la pompe et en retirant manuellement les d bris de la cage de filtration S il y a...

Страница 15: ...ontre au del des indicateurs et en tirant pour le d loger Ceci exposera l assemblage de la turbine pour une meilleure inspection Enlevez soigneusement la turbine de la pompe tout en prenant garde de n...

Страница 16: ...uvercle du r servoir inspectez et nettoyez l assemblage du rotor de turbine et la partie interne de la pompe Assurez vous que rien ne bloque ou n est envelopp autour de la turbine Assurez vous que la...

Отзывы: