background image

Ultra

 Pump Specs

Model Number

400

550

800

1100

1500

2000

Item Number

#91005

#91006

#91007

#91008

#91009

#91010

Maximum Flow Rate

370 GPH

528 GPH

793 GPH

1110 GPH

1480 GPH

1982 GPH

Maximum Head Height

7.55 ft

7.87 ft

9.19 ft

12.14 ft

16.4 ft

20.01 ft

Motor Type

Mag-Drive

Mag-Drive

Mag-Drive

Mag-Drive

Mag-Drive

Mag-Drive

Wattage

24

33

58

92

153

250

Amperage

.40

.55

.80

.85

1.46

2.60

Power Cord Length

12 ft

12 ft

25 ft

25 ft

25 ft

25 ft

Discharge Hose Diameter

½", ¾", 1", 1¼"

½", ¾", 1", 1¼"

½", ¾", 1", 1¼"

¾", 1", 1¼"

¾", 1", 1¼", 1½"

¾", 1", 1¼", 1½"

Warranty

3 Year Limited

3 Year Limited

3 Year Limited

3 Year Limited

3 Year Limited

3 Year Limited

5

www.aquascapeinc.com | 

☎ 

CAN 1-866-766-3426 | 

☎ 

US 1-866-877-6637

Typical Installation in a Pond or Decorative Fountain

•   The  Ultra

 Pump is designed to be submerged directly into 

the pond or decorative fountain container. To maximize pond 
circulation, locate the pump as far away as possible from the 
location of the water entering back into the water feature.

Pond with external filter

Decorative Fountain

•  The Multi Hose Adapter will accommodate  

different diameters of tubing.

•  The Ultra

 Pump includes an assortment of fittings to 

choose from. Select the appropriate fitting(s) needed for 
your application. Slip the O-ring seal over the threaded 
portion of the fitting.

•  The Ultra

 Pump is designed with a base that orientates 

the discharge vertically. If space is limited or plumbing  
set-up requires the discharge to be positioned horizontally, 
the pump can be positioned on its side. 

•  It is recommended that the pump 

NOT

 be positioned in 

the deepest area of the pond. This will protect the fish by 
preventing the pond from completely draining in the case of 
leak in the plumbing or filter. Bricks or stones can be used,  
if needed, to raise the pump up off the bottom of the pond.

91054 - 91005, 91006, 91007, 91008, 91009, 91010 Ultra Pump Instructions D7.indd   5

10/3/14   3:12 PM

Содержание Signature series 400

Страница 1: ...mp For Models 400 Item 91005 550 Item 91006 800 Item 91007 1100 Item 91008 1500 Item 91009 2000 Item 91010 Available in flow rates from 400 to 2000 GPH I N S T R U C T I O N S M A I N T E N A N C E Ul...

Страница 2: ...efective No liability for loss or damage of any nature or kind whether arising out of or from the use of the product whether defective or not defective is assumed by Aquascape Inc or its affiliates Co...

Страница 3: ...r 8 1 1 Multi Hose Adapter 9 Barb Valve 1 Front Cover 2 Filter Sponge 3 Water Chamber Assembly 5 Impeller Assembly 5 Rubber Feet 6 Main Housing 7 Back Cover 8 x 1 1 Multi Hose Adapter 9 3 way Valve 10...

Страница 4: ...o lift pump Installation Always operate the pump fully submerged Failure to do so will overheat the pump and cause it to fail thus voiding the warranty DO NOT OPERATE DRY Use only in fully assembled s...

Страница 5: ...ative fountain container To maximize pond circulation locate the pump as far away as possible from the location of the water entering back into the water feature Pond with external filter Decorative F...

Страница 6: ...tected by a ground fault interrupter Once the pump is running and water is circulating through the filter s or waterfalls check for any fitting or waterfall leaks where the external connections are ma...

Страница 7: ...ler Kits are available through your local Aquascape dealer 1a Note the orientation of parts in the photo below The replacement impeller kits include all parts shown Make sure to remove all of the orig...

Страница 8: ...rotor assembly and internal pump body Make sure nothing is blocking or wrapped around the impeller Make sure the pump is receiving the correct voltage Pump Not Working The ground fault circuit interru...

Страница 9: ...no 91005 550 article no 91006 800 article no 91007 1100 article no 91008 1500 article no 91009 2000 article no 91010 Disponible en d bits de 1514 7570 L h Ultra MC 400 550 800 1100 Ultra MC 1500 2000...

Страница 10: ...uts dans les mat riaux et les d fauts de fabrication seulement Le remplacement de l unit d fectueuse par une unit de rechange appropri e sera la seule obligation Les unit s devront tre v rifi es afin...

Страница 11: ...usqu 86 36 cm Jusqu 55 88 cm Jusqu 218 44 cm UltraMC 2000 91046 Jusqu 91 44 cm Jusqu 60 96 cm Jusqu 243 84 cm Cloche d eau Jet moussant Fontaine marguerite Trousse de t tes de fontaines Mod le de pomp...

Страница 12: ...son utilisation sinon elle pourrait surchauffer entra nant ainsi sa d faillance et annulant de ce fait la garantie NE FAITES PAS FONCTIONNER LA POMPE SEC Utilisez seulement lorsque la pompe est enti r...

Страница 13: ...lan d eau ou une fontaine d corative La pompe UltraMC est con ue pour tre submerg e directement dans le plan d eau ou le r servoir de la fontaine d corative Pour maximiser la circulation d eau dans le...

Страница 14: ...filtration de la pompe Dans de nombreux cas la cage de filtration bouch e peut tre nettoy e en plongeant la main dans la pompe et en retirant manuellement les d bris de la cage de filtration S il y a...

Страница 15: ...ontre au del des indicateurs et en tirant pour le d loger Ceci exposera l assemblage de la turbine pour une meilleure inspection Enlevez soigneusement la turbine de la pompe tout en prenant garde de n...

Страница 16: ...uvercle du r servoir inspectez et nettoyez l assemblage du rotor de turbine et la partie interne de la pompe Assurez vous que rien ne bloque ou n est envelopp autour de la turbine Assurez vous que la...

Отзывы: